Literature DB >> 10893816

Environmental monitoring of nitrous oxide during dental anaesthesia.

K A Henderson1, I P Matthews.   

Abstract

AIM: The study was carried out to see if levels of nitrous oxide in dental theatres and community dental clinics were being controlled in accordance with the Control of Substances Hazardous to Health Regulations.
SETTING: A multi-centre study looked at exposure levels in a dental teaching hospital and two community dental clinics in the South Wales area between 1997 and 1998.
METHODS: A MIRAN infra-red spectrophotometer was used to measure static levels of nitrous oxide during general anaesthesia and conscious sedation. NIOSH method 6600 was used to collect personal samples of the individual administering the anaesthetic.
RESULTS: The results showed compliance with the regulations when averaged out over an 8 hour time weighted average. However, over short periods of time peak concentrations of up to 1190 ppm were observed through static sampling, and up to 734 ppm through personal sampling.
CONCLUSIONS: The results highlighted the need to provide adequate control measures such as anaesthetic gas scavenging, to reduce occupational exposure to dental staff in dental operating theatres and community dental clinics, therefore providing a safe working environment.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10893816     DOI: 10.1038/sj.bdj.4800556

Source DB:  PubMed          Journal:  Br Dent J        ISSN: 0007-0610            Impact factor:   1.626


  2 in total

1.  Occupational hazards to dental staff.

Authors:  Jamshid Ayatollahi; Fatemah Ayatollahi; Ali Mellat Ardekani; Rezvan Bahrololoomi; Jahangir Ayatollahi; Ali Ayatollahi; Mohammad Bagher Owlia
Journal:  Dent Res J (Isfahan)       Date:  2012-01

2.  Exposure of paediatric healthcare personnel to nitrous oxide in paediatric care units.

Authors:  Marie-Agnès Denis; Charlotte Pete-Bonneton; Benjamin Riche; Robert Cadot; Amélie Massardier-Pilonchery; Jean Iwaz; Barbara Charbotel
Journal:  Ind Health       Date:  2021-10-25       Impact factor: 2.707

  2 in total