Literature DB >> 10893096

Treatment, airway and compliance effects of a titratable oral appliance.

A A Lowe1, T T Sjöholm, C F Ryan, J A Fleetham, K A Ferguson, J E Remmers.   

Abstract

STUDY
OBJECTIVES: To measure the effects of a titratable anterior mandibular repositioner on airway size and Obstructive Sleep Apnea (OSA) and to evaluate its compliance.
DESIGN: Before and after insertion sleep studies were obtained in a total of 38 OSA patients of varying severity from three different sites. Covert compliance was measured by means of a newly-developed, miniaturized, temperature-sensitive, imbedded monitor. Validity testing was completed in six adult volunteers who wore monitors imbedded into small acrylic appliances. MEASUREMENTS AND
RESULTS: The mean RDI before treatment was 32.6 (SEM 2.1) and after the insertion of the appliance, the RDI was reduced to 12.1 (SEM 1.7, p<0.001). RDI was reduced to less than 15/hour in 80% of a group of moderate OSA patients (RDI 15 to 30) and in 61% of a group of severe OSA patients (RDI > 30) with respect to baseline RDI. Fiber optic video endoscopy was performed on 9 OSA patients with and without the appliance. No significant differences in hypopharynx or oropharynx cross sectional areas were found, but at the level of the velopharynx, the airway size was significantly increased (p<0.05). The index of agreement was 0.99 between the monitor clock time and the subject's log sheets. Compliance data from eight OSA subjects instructed to wear the appliance during sleep indicated that it was worn for a mean of 6.8 hours with a range of 5.6 to 7.5 hours per night.
CONCLUSION: The titratable adjustable mandibular advancement appliance, made from thermoelastic acrylic, significantly reduces RDI in moderate to severe OSA patients, has a direct effect on airway size and is well worn throughout the night.

Entities:  

Mesh:

Year:  2000        PMID: 10893096

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  28 in total

1.  Oral Appliance Therapy for the Management of Sleep Disordered Breathing: An Overview.

Authors:  Robert R. Rogers
Journal:  Sleep Breath       Date:  2000       Impact factor: 2.816

2.  The impact of anatomic manipulations on pharyngeal collapse: results from a computational model of the normal human upper airway.

Authors:  Yaqi Huang; David P White; Atul Malhotra
Journal:  Chest       Date:  2005-09       Impact factor: 9.410

3.  The effect of oral appliance therapy on blood pressure in patients with obstructive sleep apnea.

Authors:  Ryo Otsuka; Fernanda Ribeiro de Almeida; Alan A Lowe; Wolfgang Linden; Frank Ryan
Journal:  Sleep Breath       Date:  2006-03       Impact factor: 2.816

Review 4.  Oral appliances for obstructive sleep apnoea.

Authors:  J Lim; T J Lasserson; J Fleetham; J Wright
Journal:  Cochrane Database Syst Rev       Date:  2006-01-25

5.  A robust method for finely stratified familial studies with proband-based sampling.

Authors:  Molin Wang; John J Hanfelt
Journal:  Biostatistics       Date:  2009-02-06       Impact factor: 5.899

6.  Forces created by mandibular advancement devices in OSAS patients: a pilot study during sleep.

Authors:  J Cohen-Levy; B Pételle; J Pinguet; E Limerat; B Fleury
Journal:  Sleep Breath       Date:  2012-09-11       Impact factor: 2.816

7.  The efficacy of a mandibular advancement splint in relation to cephalometric variables.

Authors:  Margot A Skinner; Christopher J Robertson; Ruth N Kingshott; David R Jones; D Robin Taylor
Journal:  Sleep Breath       Date:  2002-09       Impact factor: 2.816

8.  Multidisciplinary management of the airway in a trauma-induced brain injury patient.

Authors:  Jacques R Conaway; Steven C Scherr
Journal:  Sleep Breath       Date:  2004-09       Impact factor: 2.816

9.  Effect of a titration polysomnogram on treatment success with a mandibular repositioning appliance.

Authors:  Fernanda R Almeida; Jonathan A Parker; James S Hodges; Alan A Lowe; Kathleen A Ferguson
Journal:  J Clin Sleep Med       Date:  2009-06-15       Impact factor: 4.062

10.  Effects of an oral appliance with different mandibular protrusion positions at a constant vertical dimension on obstructive sleep apnea.

Authors:  Ghizlane Aarab; Frank Lobbezoo; Hans L Hamburger; Machiel Naeije
Journal:  Clin Oral Investig       Date:  2009-06-18       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.