Literature DB >> 10892954

Pneumoperitoneum secondary to endoscopic harvest of saphenous vein graft.

A Lehmann1, J Lang, U Weisse, J Boldt.   

Abstract

Endoscopic harvest of saphenous vein graft for coronary artery bypass grafting decreases leg wound complications compared with traditional longitudinal incision. A case of pneumoperitoneum secondary to endoscopic harvest of saphenous vein using insufflation of carbon dioxide is reported. Hypercarbia, increased peak airway pressure, but no significant changes of hemodynamics, or myocardial ischemia were noted. The management of this rare complication is described.

Entities:  

Mesh:

Year:  2000        PMID: 10892954     DOI: 10.1016/s0003-4975(00)01208-x

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  1 in total

1.  Absorption of carbon dioxide during endoscopic vein harvest.

Authors:  Carlo Zingaro; Michele Danilo Pierri; Francesco Massi; Marco Luciano Sacha Matteucci; Filippo Capestro; Alessandro D'Alfonso; Carlo Aratari; Lucia Torracca
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-07-02
  1 in total