| Literature DB >> 10892599 |
J Pi1, Y Kumagai, G Sun, N Shimojo.
Abstract
An improved method has been developed for the determination of L-arginine and its methylated metabolites, N(G)-monomethyl-L-arginine (L-NMMA), N(G),N(G)-dimethyl-L-arginine (asymmetric DMA, ADMA) and N(G),N(G)'-dimethyl-L-arginine (symmetric DMA, SDMA) in biological samples. Extraction of these compounds with a strong cation-exchange resin AG50W-X8 with L-homoarginine (2-amino-6-guanidinohexanoic acid) as an internal standard gave a recovery of more than 70% except for SDMA from plasma samples. After extracted samples were converted to fluorescent derivatives with o-phthalaldehyde (OPA) in an alkaline medium, the following high-performance liquid chromatographic separation with a ODS column (wide-pore size, 300 A) was successfully performed with an isocratic mobile phase system. The method permits quantitative determination of L-arginine and its methylated metabolites at concentrations as low as 4 microM and 0.18 microM, respectively. Using this method, the levels of L-arginine, L-NMMA, ADMA and SDMA in human plasma, urine and rat tissue were determined.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10892599 DOI: 10.1016/s0378-4347(00)00145-6