An improved technique for breast cancer irradiation including the locoregional lymph nodes.

C W Hurkmans1, A E Saarnak, B R Pieters, J H Borger, I A Bruinvis.   

Abstract

PURPOSE: To find an irradiation technique for locoregional irradiation of breast cancer patients which, compared with a standard technique, improves the dose distribution to the internal mammary-medial supraclavicular (IM-MS) lymph nodes. The improved technique is intended to minimize the lung dose and reduce the dose to the heart. METHODS AND MATERIALS: The standard technique consists of an anterior mixed electron/photon IM-MS field. In the improved technique, an oblique electron and an oblique asymmetric photon field are combined to irradiate the IM lymph nodes. To irradiate the MS lymph nodes, a combination of an anterior electron and an anterior asymmetric photon field is used. For both the standard and the improved technique, tangential photon fields are used to irradiate the breast. Three-dimensional (3D) treatment planning was performed for 8 patients with various breast sizes for these two techniques. Dose-volume histograms (DVHs) and normal tissue complication probabilities (NTCPs) were compared for both techniques. The field dimensions and energy of the standard technique were determined at simulation, whereas for the improved technique the fields were designed by CT-based treatment planning.
RESULTS: The dose in the breast planning target volume was essentially the same for both techniques. For the improved technique, combined with 3D localization information, an improvement in the IM-MS planning target coverage is seen. The volume within the 95% isodose surface was on average 25% (range, 0-64%) and 74% (range, 43-90%) for the standard and improved technique, respectively. The heart generally receives less dose with the improved technique. However, sometimes a small but acceptable increase in lung dose is found.
CONCLUSION: The improved technique, combined with localization information of the IM-MS lymph nodes, greatly improves the dose distribution in the planning target volume for a large group of patients without significantly increasing the dose to organs at risk.

Entities:  

Mesh:

Year:  2000        PMID: 10889397     DOI: 10.1016/s0360-3016(00)00504-6

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

1.  Segmented photon beams technique for irradiation of postmastectomy patients.

Authors:  Anna Semaniak; Zbigniew Jodkiewicz; Anna Skowrońska-Gardas
Journal:  Rep Pract Oncol Radiother       Date:  2012-03-08

2.  A novel technique for post-mastectomy breast irradiation utilising non-coplanar intensity-modulated radiation therapy.

Authors:  M Koshy; B Zhang; S Naqvi; B Liu; M M Mohiuddin
Journal:  Br J Radiol       Date:  2010-03-11       Impact factor: 3.039

3.  Risk of treatment-related esophageal cancer among breast cancer survivors.

Authors:  L M Morton; E S Gilbert; P Hall; M Andersson; H Joensuu; L Vaalavirta; G M Dores; M Stovall; E J Holowaty; C F Lynch; R E Curtis; S A Smith; R A Kleinerman; M Kaijser; H H Storm; E Pukkala; R E Weathers; M S Linet; P Rajaraman; J F Fraumeni; L M Brown; F E van Leeuwen; S D Fossa; T B Johannesen; F Langmark; S Lamart; L B Travis; B M P Aleman
Journal:  Ann Oncol       Date:  2012-06-27       Impact factor: 32.976

4.  Comparison of Chest Wall and Lymphatic Radiotherapy Techniques in Patients with Left Breast Carcinoma.

Authors:  Melis Gültekin; Mehmet Karabuğa; Ferah Yıldız; Gökhan Özyiğit; Mustafa Cengiz; Faruk Zorlu; Fadıl Akyol; Murat Gürkaynak
Journal:  J Breast Health       Date:  2014-04-01

5.  An improved internal mammary irradiation technique in radiation treatment of locally advanced breast cancers.

Authors:  Jian-Yue Jin; Eric E Klein; Feng-Ming Kong; Zuofeng Li
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

6.  HDR brachytherapy combined with 3-D conformal vs. IMRT in left-sided breast cancer patients including internal mammary chain: comparative analysis of dosimetric and technical parameters.

Authors:  Rajesh Ashok Kinhikar; Sudesh Sharad Deshpande; Umesh Mahantshetty; Rajiv Sarin; Shyam Kishore Shrivastava; Deepak Dattatraya Deshpande
Journal:  J Appl Clin Med Phys       Date:  2005-08-12       Impact factor: 2.102

7.  Radiation pneumonitis in breast cancer patients who received radiotherapy using the partially wide tangent technique after breast conserving surgery.

Authors:  Yoonsun Chung; Hong In Yoon; Yong Bae Kim; Seung Kwon Ahn; Ki Chang Keum; Chang-Ok Suh
Journal:  J Breast Cancer       Date:  2012-09-28       Impact factor: 3.588

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.