Literature DB >> 10888942

Accuracy of atlantoaxial transarticular screw insertion.

T Fuji1, T Oda, Y Kato, S Fujita, M Tanaka.   

Abstract

STUDY
DESIGN: The accuracy and safety of atlantoaxial transarticular screw insertion were evaluated in clinical cases.
OBJECTIVES: To evaluate the accuracy and safety of atlantoaxial transarticular screw insertion under lateral fluoroscopic monitoring without opening the joint. SUMMARY OF BACKGROUND DATA: Atlantoaxial transarticular screw fixation has been reported to be biomechanically superior to posterior atlantoaxial wiring techniques. Several clinical series have been reported in the literature. In some reports, the risk of screw insertion in this technique has been pointed out.
MATERIALS AND METHODS: Fifty-six consecutive patients with atlantoaxial instability were treated by transarticular screw fixation. One hundred twelve screw insertions in these 56 patients were assessed by surgical record and computed tomographic examination. One screw could not be inserted because of the difficulty of adequate placement during operation; 111 screws were therefore inserted. Adequate position was defined as when the screw perforated the lateral atlantoaxial joint.
RESULTS: In this series, neither vertebral artery injury nor spinal cord injury was experienced clinically. One guide wire was broken during drilling with a cannulated drill. Computed tomographic examination demonstrated that 106 screws perforated the atlantoaxial joint. Therefore, 95.5% of screws were adequately positioned. There were two screws positioned lateral to the joint, two medially, and one anteroinferiorly to the joint.
CONCLUSIONS: Atlantoaxial transarticular screw insertion using image intensifier without opening the lateral joint was performed safely, but not accurately, in all cases.

Entities:  

Mesh:

Year:  2000        PMID: 10888942     DOI: 10.1097/00007632-200007150-00004

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

1.  Unilateral posterior atlantoaxial transarticular screw fixation in patients with atlantoaxial instability : comparison with bilateral method.

Authors:  Yun Hee Hue; Hyoung-Joon Chun; Hyeong-Joong Yi; Seong Hoon Oh; Suck Jun Oh; Yong Ko
Journal:  J Korean Neurosurg Soc       Date:  2009-03-31

2.  A clinical morphologic study of the C2 pedicle and isthmus.

Authors:  Feng Yuan; Hui-Lin Yang; Kai-Jin Guo; Jiang-Shan Li; Kai Xu; Zhi-Ming Zhang; Tian-Si Tang
Journal:  Eur Spine J       Date:  2012-08-14       Impact factor: 3.134

3.  Potential intraoperative factors of screw-related complications following posterior transarticular C1-C2 fixation: a systematic review and meta-analysis.

Authors:  Ivan Lvov; Andrey Grin; Aleksandr Talypov; Anton Kordonskiy; Vladimir Smirnov; Iliya Grigoriev; Ulugbek Khushnazarov; Vladimir Krylov
Journal:  Eur Spine J       Date:  2018-11-22       Impact factor: 3.134

4.  Mini-open approach combined with percutaneous transarticular screw fixation for C1-C2 fusion.

Authors:  H ElSaghir; H Boehm; R Greiner-Perth
Journal:  Neurosurg Rev       Date:  2004-11-18       Impact factor: 3.042

5.  Computer-assisted screw insertion for cervical disorders in rheumatoid arthritis.

Authors:  Jun Takahashi; Yasuhiro Shono; Isao Nakamura; Hiroki Hirabayashi; Mikio Kamimura; Sohei Ebara; Hiroyuki Kato
Journal:  Eur Spine J       Date:  2006-10-06       Impact factor: 3.134

6.  Percutaneous atlantoaxial anterior transarticular screw fixation combined with mini-open posterior C1/2 wire fusion for patients with a high-riding vertebral artery.

Authors:  Ai-Min Wu; Xiang-Yang Wang; Feng Zhou; Xiao-Lei Zhang; Hua-Zi Xu; Yong-Long Chi
Journal:  J Spinal Cord Med       Date:  2016-02-11       Impact factor: 1.985

7.  A novel method of C1-C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block: A case report and a technical note.

Authors:  Kuo-Yuan Huang; Ruey-Mo Lin; Jing-Jing Fang
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

  7 in total