Validation of an endogenous reference technique for the calibration of microdialysis catheters.

L Strindberg1, P Lönnroth.   

Abstract

In order to validate the use of urea as an internal reference for the calibration of microdialysis catheters, both subcutaneous and muscle measurements were taken in 11 healthy volunteers. The equilibration calibration of urea, glucose and lactate, and the internal reference (3H-glycerol retrodialysis) calibration of glycerol were performed in both the muscle and fat. These data were then compared with those taken from the arterial plasma. Based on the average arterial-interstitial fluid concentration difference, the urea microdialysis relative recovery was estimated from dialysate and plasma content of urea. Interstitial urea was then used as an endogenous reference for the calculation of the relative recovery of each substance. This was carried out after defining the relative recovery ratios (RR) that were obtained from in vitro measurements on crystalline solutions with the assumption that RR in vivo = RR in vitro. The data demonstrate that the interstitial fluid concentrations of glucose, lactate and glycerol can be calculated from the knowledge of plasma and microdialysate content of urea together with the RR in vitro. Also, the data that were obtained using urea as an endogenous reference showed a significant correlation with those that were achieved using either equilibration or internal reference (retrodialysis) techniques for calibrating the microdialysis devices.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10885492     DOI: 10.1080/003655100750044857

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  6 in total

1.  Validation of a new calibration method for human muscle microdialysis at rest and during exercise.

Authors:  N Desvigne; J C Barthélémy; F Bertholon; J P Gay-Montchamp; D Freyssenet; F Costes
Journal:  Eur J Appl Physiol       Date:  2004-04-20       Impact factor: 3.078

Review 2.  A Review on Microdialysis Calibration Methods: the Theory and Current Related Efforts.

Authors:  Chun Min Kho; Siti Kartini Enche Ab Rahim; Zainal Arifin Ahmad; Norazharuddin Shah Abdullah
Journal:  Mol Neurobiol       Date:  2016-05-17       Impact factor: 5.590

3.  Major differences in noradrenaline action on lipolysis and blood flow rates in skeletal muscle and adipose tissue in vivo.

Authors:  V Quisth; S Enoksson; E Blaak; E Hagström-Toft; P Arner; J Bolinder
Journal:  Diabetologia       Date:  2005-03-19       Impact factor: 10.122

4.  AAPS-FDA workshop white paper: microdialysis principles, application and regulatory perspectives.

Authors:  Chandra S Chaurasia; Markus Müller; Edward D Bashaw; Eva Benfeldt; Jan Bolinder; Ross Bullock; Peter M Bungay; Elizabeth C M DeLange; Hartmut Derendorf; William F Elmquist; Margareta Hammarlund-Udenaes; Christian Joukhadar; Dean L Kellogg; Craig E Lunte; Carl Henrik Nordstrom; Hans Rollema; Ronald J Sawchuk; Belinda W Y Cheung; Vinod P Shah; Lars Stahle; Urban Ungerstedt; Devin F Welty; Helen Yeo
Journal:  Pharm Res       Date:  2007-03-27       Impact factor: 4.580

5.  Clinical evaluation of extracellular ADMA concentrations in human blood and adipose tissue.

Authors:  Marcus May; Sandor Batkai; Alexander A Zörner; Dimitrios Tsikas; Jens Jordan; Stefan Engeli
Journal:  Int J Mol Sci       Date:  2014-01-17       Impact factor: 5.923

6.  Enhanced human tissue microdialysis using hydroxypropyl-ß-cyclodextrin as molecular carrier.

Authors:  Marcus May; Sandor Batkai; Alexander A Zoerner; Dimitrios Tsikas; Jens Jordan; Stefan Engeli
Journal:  PLoS One       Date:  2013-04-05       Impact factor: 3.240