Literature DB >> 10884725

Characteristics of small lung cancers invisible on conventional chest radiography and detected by population based screening using spiral CT.

S Sone1, F Li, Z G Yang, S Takashima, Y Maruyama, M Hasegawa, J C Wang, S Kawakami, T Honda.   

Abstract

Conventional chest radiography (CXR) is a poor diagnostic tool for detecting lung cancers at a surgically curable stage. To determine the visibility of peripheral small lung cancers on CXR, we retrospectively examined the usefulness of CXR using a consecutive series of 44 cases detected on CT screening and later confirmed by histopathology. All cases had been detected by low dose CT during a population based screening trial for lung cancer. The control group consisted of 48 chest radiographs of normal subjects. Tumour diameters ranged from 6 mm to 45 mm, with 95% (42/44) < or = 20 mm, and 5% (2/44) > 20 mm. CXR failed to detect 77% (34/44) of all cancers, including 79% (33/42) < or = 20 mm and 50% (1/2) > 20 mm. Of the 42 lung cancers < or = 20 mm, 74% (31/42) were located in the well penetrated lung zones and 71% (22/31) of these were missed on CXR. 26% (11/42) were concealed by hilar vessels, mediastinum, heart or diaphragm, and all (11/11) of these were missed on CXR. 93% (39/42) of the lung cancers < or = 20 mm were adenocarcinomas and 79% (31/39) of these were missed on CXR. 7% (3/42) were epidermoid carcinomas or small cell carcinomas and 66% (2/3) of these were missed on CXR. The overall accuracy of interpretation on CXR for lung cancers was 61%, sensitivity was 23% and specificity 96%. Although there was an association between presence of lung cancer and positive reading of CXR (chi 2 test of association, p < 0.05), the percentage of positive readings was only 23%. Thus, CXR was poor at visualizing CT detectable lung cancers of < or = 20 mm diameter, which are usually of very low density, and cannot be relied upon for detection of surgically curable small lung cancer.

Entities:  

Mesh:

Year:  2000        PMID: 10884725     DOI: 10.1259/bjr.73.866.10884725

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  20 in total

1.  Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists.

Authors:  Katharina Marten; Tobias Seyfarth; Florian Auer; Edzard Wiener; Andreas Grillhösl; Silvia Obenauer; Ernst J Rummeny; Christoph Engelke
Journal:  Eur Radiol       Date:  2004-07-03       Impact factor: 5.315

Review 2.  The use of "overall accuracy" to evaluate the validity of screening or diagnostic tests.

Authors:  Anthony J Alberg; Ji Wan Park; Brant W Hager; Malcolm V Brock; Marie Diener-West
Journal:  J Gen Intern Med       Date:  2004-05       Impact factor: 5.128

3.  Detection of noncalcified pulmonary nodules on low-dose MDCT: comparison of the sensitivity of two CAD systems by using a double reference standard.

Authors:  A R Larici; M Amato; P Ordóñez; F Maggi; L Menchini; A Caulo; L Calandriello; G Vallati; S Giunta; M Crecco; L Bonomo
Journal:  Radiol Med       Date:  2012-02-10       Impact factor: 3.469

Review 4.  Principles of cancer screening: lessons from history and study design issues.

Authors:  Jennifer M Croswell; David F Ransohoff; Barnett S Kramer
Journal:  Semin Oncol       Date:  2010-06       Impact factor: 4.929

5.  Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings.

Authors:  Katharina Marten; Andreas Grillhösl; Tobias Seyfarth; Silvia Obenauer; Ernst J Rummeny; Christoph Engelke
Journal:  Eur Radiol       Date:  2004-12-02       Impact factor: 5.315

6.  Effect of gravitation for detection of bronchioloalveolar carcinoma on computed tomography.

Authors:  Takahiko Misao; Kanji Minamoto; Hideharu Nakano; Masataka Yamane; Yosuke Yamamoto; Katashi Satoh
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-06

7.  Pulmonary nodule detection on MDCT images: evaluation of diagnostic performance using thin axial images, maximum intensity projections, and computer-assisted detection.

Authors:  A Jankowski; T Martinelli; J F Timsit; C Brambilla; F Thony; M Coulomb; G Ferretti
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

8.  Enhanced CT images by the wavelet transform improving diagnostic accuracy of chest nodules.

Authors:  Xiuhua Guo; Xiangye Liu; Huan Wang; Zhigang Liang; Wei Wu; Qian He; Kuncheng Li; Wei Wang
Journal:  J Digit Imaging       Date:  2009-11-24       Impact factor: 4.056

9.  Lung cancer screening with low-dose helical CT in Korea: experiences at the Samsung Medical Center.

Authors:  Semin Chong; Kyung Soo Lee; Myung Jin Chung; Tae Sung Kim; Hojoong Kim; O Jung Kwon; Yoon-Ho Choi; Chong H Rhee
Journal:  J Korean Med Sci       Date:  2005-06       Impact factor: 2.153

10.  Relationship between tumor size and disease stage in non-small cell lung cancer.

Authors:  Fu Yang; Haiquan Chen; Jiaqing Xiang; Yawei Zhang; Jianhua Zhou; Hong Hu; Jie Zhang; Xiaoyang Luo
Journal:  BMC Cancer       Date:  2010-09-02       Impact factor: 4.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.