Literature DB >> 10884203

Results of an uncemented straight femoral shaft prosthesis after 9 years of follow-up.

C Eingartner1, R Volkmann, E Winter, F Maurer, G Sauer, S Weller, K Weise.   

Abstract

The first consecutive 250 implantations of an uncemented, proximally anchored straight femoral shaft prosthesis (BiCONTACT) in 236 patients are included in this prospective follow-up study. Average time of follow-up evaluation was 8.9 years (range, 7.4-10.7 years). At follow-up, 27 patients had died, and 2 could not be located. Seven patients underwent revision-2 for infection, 1 for recurrent dislocation, 2 for component undersizing with rapid subsidence, and 1 for aseptic loosening of a varus-malaligned stem; 1 radiologically well-fixed stem had been revised during acetabular revision. Overall survival was 97.1% after 11 years (confidence limits, 98.7% [upper] and 93.6% [lower]). The average Harris Hip score at time of follow-up was 84.3 points. Radiologically, tiny reactive lines (<2 mm) were present in the distal zones of the femoral shaft, but no radiolucencies could be found in the proximal anchoring zone. The midterm to long-term follow-up results with the evaluated femoral component are encouraging and are comparable to those of modern techniques of cementing in primary total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10884203     DOI: 10.1054/arth.2000.5265

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  [Cement-free and cemented Excia hip shaft prosthesis: comparison of intermediate term results].

Authors:  C Urschel; M Döring; W Strecker
Journal:  Orthopade       Date:  2014-09       Impact factor: 1.087

Review 2.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

3.  Does Proximally Coated Single-Wedge Cementless Stem Work Well in Dorr Type C Femurs? Minimum 10-year Followup.

Authors:  Jung-Taek Kim; Hyung Jun Jeong; Soong Joon Lee; Hee Joong Kim; Jeong Joon Yoo
Journal:  Indian J Orthop       Date:  2019 Jan-Feb       Impact factor: 1.251