Literature DB >> 10880428

Coronary artery fly-through using electron beam computed tomography.

P M van Ooijen1, M Oudkerk, R J van Geuns, B J Rensing, P J de Feyter.   

Abstract

BACKGROUND: Virtual reality techniques have recently been introduced into clinical medicine. This study examines the possibility of coronary artery fly-through using a dataset obtained by noninvasive coronary angiography with contrast-enhanced electron-beam computed tomography. METHODS AND
RESULTS: Ten patients were examined, and 40 to 60 transaxial tomograms (thickness, 1.5 mm; in-plane pixel dimensions, approximately 0.5x0.5 mm) were obtained after intravenous contrast injection. The datasets were processed on a graphics workstation using volume-rendering software. For fly-throughs, the contrast-enhanced lumen was made transparent and other tissue was made opaque. Then, key frames were selected in a path through the vessel, with software interpolation of frames between key frames. A typical movie contained 150 to 300 frames (10 to 15 key frames). Fly-throughs of coronary bypass grafts (n=3), left anterior descending arteries (LAD; n=6), and the intermediate branch (n=1) were reconstructed. Coronary calcifications were seen in 3 patients. The fly-through of the intermediate branch, the bypass grafts, and one of the LADs did not show any irregularities. In 2 cases, a stenosis was visible in the LAD; its presence was confirmed by conventional coronary angiography.
CONCLUSIONS: Recent developments in fast-volume rendering using special-purpose hardware in combination with noninvasive coronary angiography with electron beam computed tomography have provided the possibility of performing coronary artery fly-throughs.

Entities:  

Mesh:

Year:  2000        PMID: 10880428     DOI: 10.1161/01.cir.102.1.e6

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

Review 1.  New developments in the detection of vulnerable plaque.

Authors:  M Naghavi; M Madjid; M R Khan; R M Mohammadi; J T Willerson; S W Casscells
Journal:  Curr Atheroscler Rep       Date:  2001-03       Impact factor: 5.113

2.  New coronary imaging techniques: what to expect?

Authors:  P J de Feyter; K Nieman
Journal:  Heart       Date:  2002-03       Impact factor: 5.994

3.  Virtual coronary angioscopy using multislice computed tomography.

Authors:  S Schroeder; A F Kopp; B Ohnesorge; H Loke-Gie; A Kuettner; A Baumbach; C Herdeg; C D Claussen; K R Karsch
Journal:  Heart       Date:  2002-03       Impact factor: 5.994

4.  Coronary fly-through or virtual angioscopy using dual-source MDCT data.

Authors:  Peter M A van Ooijen; Gonda de Jonge; Matthijs Oudkerk
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.