Literature DB >> 10880103

Biocompatibility of alloys used in orthodontics evaluated by cell culture tests.

P Locci1, L Marinucci, C Lilli, S Belcastro, N Staffolani, S Bellocchio, F Damiani, E Becchetti.   

Abstract

The cytotoxicity of the most common alloys used in orthodontic appliances was determined by cell culture testing. Human gingival fibroblasts were cultured on 304 and 316 stainless steel, on brazing alloy composed of palladium (Pd), copper (Cu), and silver (Ag), and on plastic substrate (control). Studies were carried out with SEM and radiolabeled precursor incorporation. Cells were cultured in MEM without serum but with the addition of (3)H-thymidine to evaluate cell proliferation and (3)H-glucosamine to evaluate glycosaminoglycan (GAG) synthesis and secretion in the culture medium. Moreover, gingival fibroblasts were cultured in the presence of some metal ions generally released by orthodontic appliances to evaluate the cytotoxic effects of single ions. Morphologic observations with SEM and radiolabeled incorporation studies showed that 304 and 316 stainless steel were more biocompatible than the brazing alloy. Among the metal ions tested, Ag and Pd, constituents of the brazing alloy, showed the highest cytotoxicity.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10880103     DOI: 10.1002/1097-4636(20000915)51:4<561::aid-jbm3>3.0.co;2-h

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  On the biocompatibility of a novel Ti-based amorphous composite: structural characterization and in-vitro osteoblasts response.

Authors:  H Lefaix; A Asselin; P Vermaut; J-M Sautier; A Berdal; R Portier; F Prima
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

2.  In vitro evaluation of surface topographic changes and nickel release of lingual orthodontic archwires.

Authors:  Carlos Suárez; Teresa Vilar; Javier Gil; Pablo Sevilla
Journal:  J Mater Sci Mater Med       Date:  2009-10-14       Impact factor: 3.896

3.  Specific biofunctional performances of the hydroxyapatite-sodium maleate copolymer hybrid coating nanostructures evaluated by in vitro studies.

Authors:  L E Sima; A Filimon; R M Piticescu; G C Chitanu; D M Suflet; M Miroiu; G Socol; I N Mihailescu; J Neamtu; G Negroiu
Journal:  J Mater Sci Mater Med       Date:  2009-06-20       Impact factor: 3.896

4.  Toxicity of Orthodontic Brackets Examined by Single Cell Tracking.

Authors:  Morgan Wishney; Swarna Mahadevan; James Anthony Cornwell; Tom Savage; Nick Proschogo; M Ali Darendeliler; Hans Zoellner
Journal:  Toxics       Date:  2022-08-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.