Literature DB >> 10880086

Attachment of astroglial cells to microfabricated pillar arrays of different geometries.

A M Turner1, N Dowell, S W Turner, L Kam, M Isaacson, J N Turner, H G Craighead, W Shain.   

Abstract

We studied the attachment of astroglial cells on smooth silicon and arrays of silicon pillars and wells with various widths and separations. Standard semiconductor industry photolithographic techniques were used to fabricate pillar arrays and wells in single-crystal silicon. The resulting pillars varied in width from 0. 5 to 2.0 micrometer, had interpillar gaps of 1.0-5.0 micrometer, and were 1.0 micrometer in height. Arrays also contained 1.0-micromter-deep wells that were 0.5 micrometer in diameter and separated by 0.5-2.0 micrometer. Fluorescence, reflectance, and confocal light microscopies as well as scanning electron microscopy were used to quantify cell attachment, describe cell morphologies, and study the distribution of cytoskeletal proteins actin and vinculin on surfaces with pillars, wells, and smooth silicon. Seventy percent of LRM55 astroglial cells displayed a preference for pillars over smooth silicon, whereas only 40% preferred the wells to the smooth surfaces. Analysis of variance statistics performed on the data sets yielded values of p > approximately.5 for the comparison between pillar data sets and < approximately.0003 in the comparison between pillar and well data sets. Actin and vinculin distributions were highly polarized in cells found on pillar arrays. Scanning electron microscopy clearly demonstrated that cells made contact with the tops of the pillars and did not reach down into the spaces between pillars even when the interpillar gap was 5.0 microm. These experiments support the use of surface topography to direct the attachment, growth, and morphology of cells. These surfaces can be used to study fundamental cell properties such as cell attachment, proliferation, and gene expression. Such topography might also be used to modify implantable medical devices such as neural implants and lead to future developments in tissue engineering. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10880086     DOI: 10.1002/1097-4636(20000905)51:3<430::aid-jbm18>3.0.co;2-c

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  30 in total

Review 1.  Biomaterial Approaches to Modulate Reactive Astroglial Response.

Authors:  Jonathan M Zuidema; Ryan J Gilbert; Manoj K Gottipati
Journal:  Cells Tissues Organs       Date:  2018-12-05       Impact factor: 2.481

2.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

3.  Cell/surface interactions on laser micro-textured titanium-coated silicon surfaces.

Authors:  Steven Mwenifumbo; Mingwei Li; Jianbo Chen; Aboubaker Beye; Wolé Soboyejo
Journal:  J Mater Sci Mater Med       Date:  2007-01       Impact factor: 3.896

4.  Vertical silicon nanowires as a universal platform for delivering biomolecules into living cells.

Authors:  Alex K Shalek; Jacob T Robinson; Ethan S Karp; Jin Seok Lee; Dae-Ro Ahn; Myung-Han Yoon; Amy Sutton; Marsela Jorgolli; Rona S Gertner; Taranjit S Gujral; Gavin MacBeath; Eun Gyeong Yang; Hongkun Park
Journal:  Proc Natl Acad Sci U S A       Date:  2010-01-11       Impact factor: 11.205

5.  Fabrication of a dual substrate display to test roles of cell adhesion proteins in vesicle targeting to plasma membrane domains.

Authors:  Stephen J Hunt; W James Nelson
Journal:  FEBS Lett       Date:  2007-08-27       Impact factor: 4.124

6.  Vertical nanopillars for highly localized fluorescence imaging.

Authors:  Chong Xie; Lindsey Hanson; Yi Cui; Bianxiao Cui
Journal:  Proc Natl Acad Sci U S A       Date:  2011-02-22       Impact factor: 11.205

7.  Biocompatibility study of three distinct carbon pastes for application as electrode material in neural stimulations and recordings.

Authors:  Melinda Varga; Paul Wolff; Klaus-Juergen Wolter
Journal:  J Mater Sci Mater Med       Date:  2017-01-20       Impact factor: 3.896

Review 8.  Cerebrospinal Fluid Shunting Complications in Children.

Authors:  Brian W Hanak; Robert H Bonow; Carolyn A Harris; Samuel R Browd
Journal:  Pediatr Neurosurg       Date:  2017-03-02       Impact factor: 1.162

9.  Reduced cell attachment to poly(2-hydroxyethyl methacrylate)-coated ventricular catheters in vitro.

Authors:  Brian W Hanak; Chia-Yun Hsieh; William Donaldson; Samuel R Browd; Kenneth K S Lau; William Shain
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-06-20       Impact factor: 3.368

10.  Response of bone marrow derived connective tissue progenitor cell morphology and proliferation on geometrically modulated microtextured substrates.

Authors:  Eun Jung Kim; Aaron J Fleischman; George F Muschler; Shuvo Roy
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.