Literature DB >> 10876210

Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial.

C K Zarins1, R A White, K J Hodgson, D Schwarten, T J Fogarty.   

Abstract

OBJECTIVE: The purpose of this study was to determine whether evidence of blood flow in the aneurysm sac (endoleak) is a meaningful predictor of clinical outcome after successful endovascular aneurysm repair.
METHODS: We reviewed all patients in Phase II of the AneuRx Multicenter Clinical Trial with successful stent graft implantation and predischarge contrast computed tomographic (CT) imaging. The clinical outcome of patients with evidence of endoleak was compared with the outcome of patients without evidence of endoleak. The CT endoleak status before hospital discharge at 6, 12, and 24 months was determined by each clinical center as well as by an independent core laboratory. Endoleak status at 1 month was assessed with duplex scanning examination or CT at each center without confirmation by the core laboratory.
RESULTS: Centers reported endoleaks in 152 (38%) of 398 patients on predischarge CT, whereas the core laboratory reported endoleaks in 50% of these patients (P <.001). The center-reported endoleak rate decreased to 13% at 1 month. Follow-up extended to 2 years (mean, 10 +/- 4 months). One patient had aneurysm rupture and underwent successful open repair at 14 months. This patient had a Type I endoleak at discharge but no endoleak at 1 month or at subsequent follow-up times. There were no differences between patients with and patients without endoleak at discharge in the following outcome measures: patient survival, aneurysm rupture, surgical conversion, the need for an additional procedure for endoleak or graft patency, aneurysm enlargement more than 5 mm, the appearance of a new endoleak, or stent graft migration. Despite a higher endoleak rate identified by the core laboratory, neither the endoleak rate reported by the core laboratory nor the endoleak rate reported by the center at discharge was significantly related to subsequent outcome measures. Patients with endoleak at 1 month were more likely to undergo an additional procedure for endoleak than patients without endoleaks. Patients with Type I endoleaks at discharge and patients with endoleak at 1 month were more likely to experience aneurysm enlargement at 1 year. However, there was no difference in patient survival, aneurysm rupture rate, or primary or secondary success rate between patients with or without endoleak. Actuarial survival of all patients undergoing endovascular aneurysm repair was 96% at 1 year and was independent of endoleak status. Primary outcome success was 92% at 12 months and 88% at 18 months. Secondary outcome success was 96% at 12 months and 94% at 18 months.
CONCLUSIONS: The presence or absence of endoleak on CT scan before hospital discharge does not appear to predict patient survival or aneurysm rupture rate after endovascular aneurysm repair using the AneuRx stent graft. Although the identification of blood flow in the aneurysm sac after endovascular repair is a meaningful finding and may at times indicate inadequate stent graft fixation, the usefulness of endoleak as a primary indicator of procedural success or failure is unclear. Therefore, all patients who have undergone endovascular aneurysm repair should be carefully followed up regardless of endoleak status.

Entities:  

Mesh:

Year:  2000        PMID: 10876210     DOI: 10.1067/mva.2000.108278

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  16 in total

Review 1.  Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment.

Authors:  Jafar Golzarian; David Valenti
Journal:  Eur Radiol       Date:  2006-04-11       Impact factor: 5.315

2.  General versus locoregional anesthesia for endovascular aortic aneurysm repair: influences of the type of anesthesia on its outcome.

Authors:  Yusuke Asakura; Hiroyuki Ishibashi; Tsuneo Ishiguchi; Nobuhisa Kandatsu; Manabu Akashi; Toru Komatsu
Journal:  J Anesth       Date:  2009-02-22       Impact factor: 2.078

3.  Relining technique for continuous sac enlargement and modular disconnection secondary to endotension after endovascular aortic aneurysm repair.

Authors:  Moon Il Lee; Woo Young Shin; Yun Mee Choe; Jae Young Park; Jang Yong Kim; Yong Sun Jeon; Soon Gu Cho; Kee Chun Hong
Journal:  Ann Surg Treat Res       Date:  2014-02-24       Impact factor: 1.859

4.  The Safety of Using Large Amount (30 cc) of Onyx (Ethylene-vinyl Alcohol Copolymer) for the Treatment of Large Type II Endoleak after Endovascular Repair of Abdominal Aortic Aneurysm.

Authors:  Mohammad Hasan Namazi; Isa Khaheshi; Ali Reza Serati; Mohammad Reza Movahed
Journal:  Int J Angiol       Date:  2016-12-15

5.  [Endoleaks - when is treatment necessary?].

Authors:  O Dudeck
Journal:  Radiologe       Date:  2013-06       Impact factor: 0.635

Review 6.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

7.  Endoluminal graft repair for abdominal aortic aneurysms in high-risk patients and octogenarians: is it better than open repair?

Authors:  G A Sicard; B G Rubin; L A Sanchez; C A Keller; M W Flye; D Picus; D Hovsepian; E T Choi; P J Geraghty; R W Thompson
Journal:  Ann Surg       Date:  2001-10       Impact factor: 12.969

8.  CT Findings of Risk Factors for Persistent Type II Endoleak from Inferior Mesenteric Artery to Determine Indicators of Preoperative IMA Embolization.

Authors:  Tetsuya Fukuda; Hitoshi Matsuda; Yoshihiro Sanda; Yoshiaki Morita; Kenji Minatoya; Junjiro Kobayashi; Hiroaki Naito
Journal:  Ann Vasc Dis       Date:  2014-08-30

9.  Midterm outcomes of endovascular repair for abdominal aortic aneurysms with the on-label use compared with the off-label use of an endoprosthesis.

Authors:  Takuya Matsumoto; Shinichi Tanaka; Jun Okadome; Ryoichi Kyuragi; Ryota Fukunaga; Eisuke Kawakubo; Hiroyuki Itoh; Jin Okazaki; Ken Shirabe; Atsushi Fukuda; Yoshihiko Maehara
Journal:  Surg Today       Date:  2014-07-18       Impact factor: 2.549

10.  Type II endoleak with or without intervention after endovascular aortic aneurysm repair does not change aneurysm-related outcomes despite sac growth.

Authors:  Joy Walker; Lue-Yen Tucker; Philip Goodney; Leah Candell; Hong Hua; Steven Okuhn; Bradley Hill; Robert W Chang
Journal:  J Vasc Surg       Date:  2015-06-06       Impact factor: 4.268

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.