Literature DB >> 10875706

On the direct Fourier method for computer tomography.

D Gottlieb1, B Gustafsson, P Forssén.   

Abstract

The paper considers the direct Fourier methods (DFM's) for reconstructing an image from its given X-ray projections. The main purpose here is to use concepts from numerical analysis to estimate the errors in the methods. We also suggest an alternative to the interpolations involved in the DFM's and estimate the number of terms involved. Realizing that one of the main reasons for the degradation of the quality of the reconstruction is the Gibbs phenomenon, we suggest a way to overcome this difficulty and give numerical evidence of its efficacy.

Mesh:

Year:  2000        PMID: 10875706     DOI: 10.1109/42.845180

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

Authors:  Behzad Sharif; Rohan Dharmakumar; Troy LaBounty; Reza Arsanjani; Chrisandra Shufelt; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2013-09-12       Impact factor: 4.668

2.  The Three-Dimensional Morphology of Growing Dendrites.

Authors:  J W Gibbs; K A Mohan; E B Gulsoy; A J Shahani; X Xiao; C A Bouman; M De Graef; P W Voorhees
Journal:  Sci Rep       Date:  2015-07-03       Impact factor: 4.379

3.  Accelerated Compressed Sensing Based CT Image Reconstruction.

Authors:  SayedMasoud Hashemi; Soosan Beheshti; Patrick R Gill; Narinder S Paul; Richard S C Cobbold
Journal:  Comput Math Methods Med       Date:  2015-06-18       Impact factor: 2.238

4.  Low-dose Cone-Beam Computed Tomography Reconstruction through a fast Three-Dimensional Compressed Sensing Method Based on the Three-Dimensional Pseudo-polar Fourier Transform.

Authors:  N Teyfouri; Hossein Rabbani; I Jabbari
Journal:  J Med Signals Sens       Date:  2021-12-28

5.  Compensating the intensity fall-off effect in cone-beam tomography by an empirical weight formula.

Authors:  Zikuan Chen; Vince D Calhoun; Shengjiang Chang
Journal:  Appl Opt       Date:  2008-11-10       Impact factor: 1.980

6.  Compressed Sensing Electron Tomography for Determining Biological Structure.

Authors:  Matthew D Guay; Wojciech Czaja; Maria A Aronova; Richard D Leapman
Journal:  Sci Rep       Date:  2016-06-13       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.