Literature DB >> 10873483

Fluorescence intensity calibration for immunophenotyping by flow cytometry.

R F Vogt1, W E Whitfield, L O Henderson, W H Hannon.   

Abstract

Fluorescence intensity (FI) is the basis for classifying phenotypes by fluorescence-label flow cytometry. FI is customarily recorded as an arbitrary relative value, but with proper calibration it can be expressed in stoichiometric units called molecules of equivalent soluble fluorochrome (MESF) that reflect the concentrations of the fluorescent conjugates and the receptors they stain. Forthcoming availability of authoritative standards and consensus methods will alleviate many of the difficulties encountered in making valid MESF measurements. FI calibration establishes the true values for the critical parameters of the fluorescence measurement, a useful feature for quality control. It further allows the establishment of a comparable window of analysis across different times and laboratories, and it permits numeric assessment of antibody-binding capacity (ABC) values in selected cell populations. The relation between ABC values and receptor expression is complicated by several factors, but careful assessment of the binding chemistry can establish the actual number of receptors on cells stained by fluorescent conjugates.

Mesh:

Substances:

Year:  2000        PMID: 10873483     DOI: 10.1006/meth.2000.1009

Source DB:  PubMed          Journal:  Methods        ISSN: 1046-2023            Impact factor:   3.608


  4 in total

1.  Metal-Containing Polystyrene Beads as Standards for Mass Cytometry.

Authors:  Ahmed I Abdelrahman; Olga Ornatsky; Dmitry Bandura; Vladimir Baranov; Robert Kinach; Sheng Dai; Stuart C Thickett; Scott Tanner; Mitchell A Winnik
Journal:  J Anal At Spectrom       Date:  2010       Impact factor: 4.023

2.  Visual inspection versus quantitative flow cytometry to detect aberrant CD2 expression in malignant T cells.

Authors:  Indu Arun; Jacqueline A Wulu; John E Janik; Gregory A Jasper; Constance M Yuan; David Venzon; Maryalice Stetler-Stevenson
Journal:  Cytometry B Clin Cytom       Date:  2010-05       Impact factor: 3.058

3.  Atherosclerosis Risk in Communities (ARIC) Carotid MRI flow cytometry study of monocyte and platelet markers: intraindividual variability and reliability.

Authors:  Diane J Catellier; Nena Aleksic; Aaron R Folsom; Eric Boerwinkle
Journal:  Clin Chem       Date:  2008-05-29       Impact factor: 8.327

4.  Flow Cytometry as a Tool for Quality Control of Fluorescent Conjugates Used in Immunoassays.

Authors:  Marta de Almeida Santiago; Bruna de Paula Fonseca E Fonseca; Christiane de Fátima da Silva Marques; Edimilson Domingos da Silva; Alvaro Luiz Bertho; Ana Cristina Martins de Almeida Nogueira
Journal:  PLoS One       Date:  2016-12-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.