Artifacts in CSI-measurements caused by the drift of the static magnetic field.

O Schmidt1, S Widmaier, M Bunse, W I Jung, G J Dietze, O Lutz.   

Abstract

In chemical shift resolved spectroscopic imaging (CSI) temporal changes in the static magnetic field (drift) can lead to distortions of the phase encoding process. This can result in localization artifacts. The extent of the artifact depends on the size of the drift, the number of acquisitions, as well as on the combination of the size of the field of view and the number of phase encoding gradient steps. Furthermore, it is affected by the succession of the phase encoding gradients. Precautions are described which allow substantial minimization of the artifact.

Mesh:

Substances:

Year:  2000        PMID: 10873207     DOI: 10.1007/bf02590642

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  4 in total

Review 1.  Practical applications of chemical shift imaging.

Authors:  T R Brown
Journal:  NMR Biomed       Date:  1992 Sep-Oct       Impact factor: 4.044

2.  Phosphorus J coupling constants of ATP in human myocardium and calf muscle.

Authors:  W I Jung; S Widmaier; U Seeger; M Bunse; A Staubert; L Sieverding; K Straubinger; F van Erckelens; F Schick; G Dietze; O Lutz
Journal:  J Magn Reson B       Date:  1996-01

3.  Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle.

Authors:  J De Poorter; C De Wagter; Y De Deene; C Thomsen; F Ståhlberg; E Achten
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

4.  NMR chemical shift imaging in three dimensions.

Authors:  T R Brown; B M Kincaid; K Ugurbil
Journal:  Proc Natl Acad Sci U S A       Date:  1982-06       Impact factor: 11.205

  4 in total
  3 in total

Review 1.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

2.  Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

Authors:  Assaf Tal; Oded Gonen
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

3.  Prospective frequency correction using outer volume suppression-localized navigator for MR spectroscopy and spectroscopic imaging.

Authors:  Chu-Yu Lee; In-Young Choi; Phil Lee
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.