Literature DB >> 10873196

An efficient geometric image distortion correction method for a biplanar planar gradient coil.

H Liu1.   

Abstract

Since the spatial field non-linearity of gradient coils translates into image geometric distortion in MRI, in many applications, such as cardiac function analysis and interventional MR-based device tracking/guidance, where the precise geometric information is needed, the presence of geometric image distortion can not be simply ignored. To address the concern for geometric image distortion, we have developed and validated a general and efficient numerical technique for parameterizing the global image distortion for a bi-planar gradient coil as well as accomplishing image restoration as a post-imaging processing. This image correction methodology is based on a global distortion coordinate mapping function which can be systematically defined directly from the gradient field non-linearity in 3-dimension (3D) of a given gradient coil. The image correction was carried out in two steps: (1) map each pixel of the corrected image representation onto its distorted image according to the distortion mapping; (2) interpolate the pixel intensity in the distorted image using its neighboring points via a bi-linear interpolation procedure. The results showed clearly that the distortion correction method was robust in term of the capability of reducing image geometric distortion dramatically. Also it is shown that the magnetic field non-linearity or the image distortion of a typical bi-planar gradient coil can be adequately parameterized using a finite Taylor series expansion based on its design parameters. Furthermore, this image distortion correction method is very efficient in practice for performing 3D correction for any image orientation since a compact parameterized field expression contains non-zero terms.

Mesh:

Year:  2000        PMID: 10873196     DOI: 10.1007/bf02601841

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  3 in total

1.  True energy-minimal and finite-size biplanar gradient coil design for MRI.

Authors:  H Liu; C L Truwit
Journal:  IEEE Trans Med Imaging       Date:  1998-10       Impact factor: 10.048

2.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities.

Authors:  M O'Donnell; W A Edelstein
Journal:  Med Phys       Date:  1985 Jan-Feb       Impact factor: 4.071

Review 3.  Gradient coil design: a review of methods.

Authors:  R Turner
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.