The anterior band of the inferior glenohumeral ligament. Assessment of its permanent deformation and the anatomy of its glenoid attachment.

P J McMahon1, J Dettling, M D Sandusky, J E Tibone, T Q Lee.   

Abstract

Surgical treatment for traumatic, anterior glenohumeral instability requires repair of the anterior band of the inferior glenohumeral ligament, usually at the site of glenoid insertion, often combined with capsuloligamentous plication. In this study, we determined the mechanical properties of this ligament and the precise anatomy of its insertion into the glenoid in fresh-frozen glenohumeral joints of cadavers. Strength was measured by tensile testing of the glenoid-soft-tissue-humerus (G-ST-H) complex. Two other specimens of the complex were frozen in the position of apprehension, serially sectioned perpendicular to the plane containing the anterior and posterior rims of the glenoid, and stained with Toluidine Blue. On tensile testing, eight G-ST-H complexes failed at the site of the glenoid insertion, representing a Bankart lesion, two at the insertion into the humerus, and two at the midsubstance. For those which failed at the glenoid attachment the mean yield load was 491.0 N and the mean ultimate load, 585.0 N. At the glenoid region, stress at yield was 7.8 +/- 1.3 MPa and stress at failure, 9.2 +/- 1.5 MPa. The permanent deformation, defined as the difference between yield and ultimate deformation, was only 2.3 +/- 0.8 mm. The strain at yield was 13.0 +/- 0.7% and at failure, 15.4 +/- 1.2%; therefore permanent strain was only 2.4 +/- 1.1%. Histological examination showed that there were two attachments of the anterior band of the inferior glenohumeral ligament at the site of the glenoid insertion. In one, poorly organised collagen fibres inserted into the labrum. In the other, dense collagen fibres were attached to the front of the neck of the glenoid.

Entities:  

Mesh:

Year:  1999        PMID: 10872356     DOI: 10.1302/0301-620x.81b3.9153

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

Review 1.  Anatomy of the capsulolabral complex and rotator interval related to glenohumeral instability.

Authors:  Yoshiaki Itoigawa; Eiji Itoi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-24       Impact factor: 4.342

2.  A large humeral avulsion of the glenohumeral ligaments decreases stability that can be restored with repair.

Authors:  Kyoung Jin Park; Mallika Tamboli; Lauren Y Nguyen; Michelle H McGarry; Thay Q Lee
Journal:  Clin Orthop Relat Res       Date:  2014-08       Impact factor: 4.176

3.  Finding consistent strain distributions in the glenohumeral capsule between two subjects: implications for development of physical examinations.

Authors:  Nicholas J Drury; Benjamin J Ellis; Jeffrey A Weiss; Patrick J McMahon; Richard E Debski
Journal:  J Biomech       Date:  2010-12-07       Impact factor: 2.712

Review 4.  Humeral Avulsion of the Glenohumeral Ligament: Indications for Surgical Treatment and Outcomes-A Systematic Review.

Authors:  Anthony Bozzo; Colby Oitment; Patrick Thornley; James Yan; Anthony Habib; Daniel J Hoppe; George S Athwal; Olufemi R Ayeni
Journal:  Orthop J Sports Med       Date:  2017-08-14

5.  Mapping of the Inferior Glenohumeral Ligament for Suture Pullout Strength: A Biomechanical Analysis.

Authors:  Sumit Raniga; Joseph Cadman; Danè Dabirrahmani; David Bui; Richard Appleyard; Desmond Bokor
Journal:  Orthop J Sports Med       Date:  2021-01-11

6.  The Bankart repair versus the Putti-Platt procedure: a randomized study with WOSI score at 10-year follow-up in 62 patients.

Authors:  Björn Salomonsson; Hassan Abbaszadegan; Suzanne Revay; Ulf Lillkrona
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

7.  Load-to-failure characteristics of patellar tendon allograft superior capsule reconstruction compared with the native superior capsule.

Authors:  Seth M Boydstun; Gregory J Adamson; Michelle H McGarry; James E Tibone; Thay Q Lee
Journal:  JSES Int       Date:  2021-05-11