Literature DB >> 10871910

Differences between dual X-ray absorptiometry using pencil beam and fan beam modes and their determinants in vivo and in vitro.

A G Ruetsche1, K Lippuner, P Jaeger, J P Casez.   

Abstract

The aim of this study was to determine the influence of individual factors on differences in bone mineral density (BMD) using dual X-ray absorptiometry pencil beam (PB) and fan beam (FB) modes in vivo and in vitro. PB.BMD and FB.BMD of 63 normal Caucasian females ages 21-80 yr were measured at the lumbar spine and hip. Residuals of the FB/PB regression were used to assess the impact of height, weight, adiposity index (AI) (= weight/height(3/2)), back tissue thickness, and PB.BMD, respectively, on FB/PB difference. The Hologic Anthropomorphic Spine Phantom (ASP) was measured using the PB and FB modes at two different levels to assess the impact of scanning mode and focus distance. The European Spine Phantom (ESP) prototype, a geometrically well-defined phantom with known vertebral densities, was measured using PB and FB modes and analyzed manually to determine the impact of bone density on FB/PB difference and automatically to determine the impact of edge detection on FB/PB difference. Population BMD results were perfectly correlated, but significantly overestimated by 1.5% at the lumbar spine and underestimated by 0.7% at the neck, 1.8% at the trochanter, and 2.0% at the total hip, respectively, when using the FB compared with PB mode. At the lumbar spine, the FB/PB residual correlated negatively with height (r = 0.34, p < 0.01) and PB.BMD (r = 0.48, p &lt: 0. 0001) and positively with AI (r = 0.26, p < 0.05). At the hip, residual of trochanter correlated positively with weight (r = 0.36, p < 0.01) and AI (r = 0.36, p < 0.01). The FB mode significantly increased ASP BMD by 0.7% compared with PB. Using the FB mode, increasing focus distance significantly (p < 0.001) decreased area and bone mineral content, but not BMD. By contrast, increasing focus distance significantly decreased PB.BMD by 0.7%. With the ESP, the PB mode supplied accurate projected are of the bone (AREA) results but significant underestimation of specified BMD in the manual analysis. The FB mode significantly underestimated PB. AREA by 2.9% but fitted specified BMD quite well. FB/PB overestimation was larger for the low-density (+8.7%) than for the high-density vertebra (+4. 9%). The automated analysis resulted in more than 14% underestimation of PB. AREA (low-density vertebra) and an almost 13% overestimation of PB.BMD (high-density vertebra) using FB. In conclusion, FB and PB measurements are highly correlated at the lumbar spine and hip with small but significant BMD differences related to height, adiposity, and BMD. In clinical practice, it can be erroneous to switch from one method to another, especially in women with low bone density.

Entities:  

Mesh:

Year:  2000        PMID: 10871910     DOI: 10.1385/jcd:3:2:157

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.963


  3 in total

1.  Correcting fan-beam magnification in clinical densitometry scans of growing subjects.

Authors:  Jacqueline H Cole; Jodi N Dowthwaite; Tamara A Scerpella; Marjolein C H van der Meulen
Journal:  J Clin Densitom       Date:  2009 Jul-Sep       Impact factor: 2.617

2.  Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

Authors:  B Fan; Y Lu; H Genant; T Fuerst; J Shepherd
Journal:  Osteoporos Int       Date:  2009-10-27       Impact factor: 4.507

3.  Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review.

Authors:  Byung-Ho Yoon; Young Do Koh; Jun-Il Yoo; Sujin Kim; Guen Young Lee; Sung Bin Park; Yong-Chan Ha
Journal:  J Bone Metab       Date:  2021-02-28
  3 in total