Evaluation of error bounds on calcaneal speed of sound caused by surrounding soft tissue.

C Chappard1, E Camus, F Lefebvre, G Guillot, J Bittoun, G Berger, P Laugier.   

Abstract

For absorptiometry measurements, soft tissue may have an impact on quantitative ultrasound (QUS) measurements. In the present study, we focused primarily on the quantification of measurement error on speed of sound (SOS) caused by surrounding soft tissue. The relevant soft tissue parameters affecting the inherent SOS inaccuracies are thickness and sound velocity. To meet our goal, SOS measurements were taken at the right heel using a QUS imaging device in 21 healthy subjects. Site-matched measurements of soft tissue thickness (STT) and bone width were performed using magnetic resonance imaging of the heel. Several bone velocities were calculated either by accounting for bone width (SOSBW) only or by taking into account the exact path lengths of all major components traversed by ultrasound &lapr;V(b)). Given that soft tissue composition is difficult to determine in vivo, we chose to estimate lower and upper error bounds on bone velocity (V(b lower) and V(b upper)) by spanning the full range of available values in the literature. The mean BW was 30.7 +/- 2.7 mm and the mean medial and external STTs were 8.8 +/- 1.7 and 8.5 +/- 1.5 mm, respectively. Accounting for true BW only resulted in no significant difference between SOS (1533 +/- 37) and SOSBW (1531 +/- 33). By contrast, accounting for both true BW and surrounding soft tissue resulted in an increase in the calculated bone velocity and statistically significant differences between SOS and V(b upper) (1568 +/- 36) and V(b lower) (1542 +/- 34). Root mean square errors between SOS and the calculated velocities were 0.34, 2. 32, and 0.70% for SOSBW, V(b upper), and V(b lower), respectively. We report here measurement errors caused by soft tissue to be 3 to 20 times higher than the SOS short-term precision (SOS coefficient of variation of 0.1%). Our results suggest that inaccuracies in SOS measurement caused by overlying soft tissue cannot be neglected. Overlying soft tissues may influence outcomes of longitudinal studies, especially if variations in tissue thickness and composition occur during the longitudinal follow-up. A practical way of minimizing the measurement error could be to perform an adequate correction for the overlying soft tissue. However, ideally, this should require knowing both the thickness and sound velocity in soft tissue. One might preferably conduct experimental investigations that directly control soft tissue thickness and composition to resolve this problem.

Entities:  

Mesh:

Year:  2000        PMID: 10871906     DOI: 10.1385/jcd:3:2:121

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.963


  8 in total

1.  A European multicenter comparison of quantitative ultrasound measurement variables: the OPUS study.

Authors:  M A Paggiosi; R Barkmann; C C Glüer; C Roux; D M Reid; D Felsenberg; M Bradburn; R Eastell
Journal:  Osteoporos Int       Date:  2012-02-14       Impact factor: 4.507

Review 2.  The use of ultrasound in the assessment of bone status.

Authors:  S Gonnelli; C Cepollaro
Journal:  J Endocrinol Invest       Date:  2002-04       Impact factor: 4.256

3.  Gene-dietary fat interaction, bone mineral density and bone speed of sound in children: a twin study in China.

Authors:  Tao Huang; Huijuan Liu; Wei Zhao; Ji Li; Youfa Wang
Journal:  Mol Nutr Food Res       Date:  2015-01-21       Impact factor: 5.914

Review 4.  Quantitative ultrasound: use in the detection of fractures and in the assessment of bone composition.

Authors:  Claus-C Glüer; Reinhard Barkmann
Journal:  Curr Osteoporos Rep       Date:  2003-12       Impact factor: 5.096

5.  Characterization of bone microstructure using photoacoustic spectrum analysis.

Authors:  Ting Feng; Joseph E Perosky; Kenneth M Kozloff; Guan Xu; Qian Cheng; Sidan Du; Jie Yuan; Cheri X Deng; Xueding Wang
Journal:  Opt Express       Date:  2015-09-21       Impact factor: 3.894

6.  Bone surface topology mapping and its role in trabecular bone quality assessment using scanning confocal ultrasound.

Authors:  Y Xia; W Lin; Y-X Qin
Journal:  Osteoporos Int       Date:  2007-03-15       Impact factor: 5.071

7.  Radial quantitative ultrasound and dual energy x-ray absorptiometry: intermethod agreement for bone status assessment in children.

Authors:  Kar Hau Chong; Bee Koon Poh; Nor Aini Jamil; Nor Azmi Kamaruddin; Paul Deurenberg
Journal:  Biomed Res Int       Date:  2015-04-01       Impact factor: 3.411

8.  Discordant effect of body mass index on bone mineral density and speed of sound.

Authors:  Miriam Steinschneider; Philippe Hagag; Micha J Rapoport; Mordechai Weiss
Journal:  BMC Musculoskelet Disord       Date:  2003-07-16       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.