Literature DB >> 10870895

Experimental and computational flow evaluation of coronary stents.

J L Berry1, A Santamarina, J E Moore, S Roychowdhury, W D Routh.   

Abstract

Local flow alterations created by a metallic stent in a simulated coronary artery were studied to compare the hemodynamic effects of two different stent geometries. Dye injection flow visualization and computational fluid dynamics were used. Resting and exercise conditions were studied. Flow visualization using the dye injection method provided a qualitative picture of stent hemodynamics while the computational approach provided detailed quantitative information on the flow next to the vessel wall near the intersections of stent wires. Dye injection visualization revealed that more dye became entrapped between the wires where the wire spacing was smallest. The dye washout times were shorter under exercise conditions for both wire spacings tested. The computational results showed that stagnation zones were continuous from one wire to the next when the wire spacing was small. Results from greater wire spacing (more than six wire diameters) showed that the stagnation zones were separate for at least part of the cardiac cycle. The sizes of the stagnation zones were larger under exercise conditions, and the largest stagnation zones were observed distal to the stent. These studies demonstrate that stent geometry has a significant effect on local hemodynamics. The observation that fluid stagnation is continuous in stents with wire spacings of less than six wire diameters may provide a criterion for future stent design.

Mesh:

Substances:

Year:  2000        PMID: 10870895     DOI: 10.1114/1.276

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  17 in total

1.  Fractal structures in stenoses and aneurysms in blood vessels.

Authors:  Adriane B Schelin; György Károlyi; Alessandro P S de Moura; Nuala A Booth; Celso Grebogi
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2010-12-28       Impact factor: 4.226

2.  Accelerated endothelialization with a polymer-free sirolimus-eluting antibody-coated stent.

Authors:  Zhanjiang Yu; Huagang Zhu; Shuzheng Lü; Xiaoda Yang
Journal:  J Mater Sci Mater Med       Date:  2013-08-23       Impact factor: 3.896

3.  Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.

Authors:  Henry Y Chen; Anjan K Sinha; Jenny S Choy; Hai Zheng; Michael Sturek; Brian Bigelow; Deepak L Bhatt; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-09-16       Impact factor: 4.733

4.  Behaviour of two typical stents towards a new stent evolution.

Authors:  M Simão; J M Ferreira; J Mora-Rodriguez; J Fragata; H M Ramos
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

5.  Direct Adsorption of Anti-CD34 Antibodies on the Nano-Porous Stent Surface to Enhance Endothelialization.

Authors:  Guowei Fu; Zhanjiang Yu; Yongqiang Chen; Yundai Chen; Feng Tian; Xiaoda Yang
Journal:  Acta Cardiol Sin       Date:  2016-05       Impact factor: 2.672

6.  Impact of main branch stenting on endothelial shear stress: role of side branch diameter, angle and lesion.

Authors:  Henry Y Chen; Issam D Moussa; Charles Davidson; Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2011-11-23       Impact factor: 4.118

7.  Simulation of the microscopic process during initiation of stent thrombosis.

Authors:  Jennifer K W Chesnutt; Hai-Chao Han
Journal:  Comput Biol Med       Date:  2014-11-15       Impact factor: 4.589

8.  Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression.

Authors:  Juan M Jiménez; Varesh Prasad; Michael D Yu; Christopher P Kampmeyer; Abdul-Hadi Kaakour; Pei-Jiang Wang; Sean F Maloney; Nathan Wright; Ian Johnston; Yi-Zhou Jiang; Peter F Davies
Journal:  J R Soc Interface       Date:  2014-02-19       Impact factor: 4.118

9.  Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  J Endovasc Ther       Date:  2008-12       Impact factor: 3.487

10.  Luminal flow patterns dictate arterial drug deposition in stent-based delivery.

Authors:  Vijaya B Kolachalama; Abraham R Tzafriri; Davis Y Arifin; Elazer R Edelman
Journal:  J Control Release       Date:  2008-09-26       Impact factor: 9.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.