Literature DB >> 10870755

Finite-element-analysis of different screw-diameters in the sagittal split osteotomy of the mandible.

P Maurer1, S Holweg, J Schubert.   

Abstract

A three dimensional finite element model of the mandible was developed to simulate and study the biomechanical loads of osteosynthesis screws in bilateral sagittal osteotomy. Using the finite-element method clinical conditions were simulated. Different bicortical screw configurations and diameters were evaluated. When bite forces were applied, the most stable configuration was found to be a triangular one. This confirms the results found in the literature. A mini screw of 2.0 mm diameter can provide sufficient stability at the osteotomy site after ramus split osteotomy. Even screws with a diameter of 1.5 mm would withstand forces up to 89.5 N, which would not normally be reached by patients after ramus split osteotomy in the early period of healing. Forces exerted by patients after bilateral ramus split osteotomy do not exceed these values. The finite-element analysis appears to be an adequate method to evaluate this clinical question of interest. It might well replace mechanical models and the results are comparable with those reported in the International literature.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10870755     DOI: 10.1054/jcms.1999.0069

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  4 in total

1.  Biomechanical evaluation of unilateral subcondylar fracture of the mandible on the varying materials: A finite element analysis.

Authors:  Bryan Taekyung Jung; Won Hyeon Kim; Byungho Park; Jong-Ho Lee; Bongju Kim; Jee-Ho Lee
Journal:  PLoS One       Date:  2020-10-08       Impact factor: 3.240

Review 2.  Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances.

Authors:  Barzi Gareb; Nico B Van Bakelen; Arjan Vissink; Ruud R M Bos; Baucke Van Minnen
Journal:  Polymers (Basel)       Date:  2022-07-07       Impact factor: 4.967

3.  Parametric analysis of orthopedic screws in relation to bone density.

Authors:  Elisabetta M Zanetti; Massimiliano Salaorno; Giovanni Grasso; Alberto L Audenino
Journal:  Open Med Inform J       Date:  2009-04-21

4.  Comparison of the mechanical properties of biodegradable and titanium osteosynthesis systems used in oral and maxillofacial surgery.

Authors:  Barzi Gareb; Charlotte C Roossien; Nico B van Bakelen; Gijsbertus J Verkerke; Arjan Vissink; Ruud R M Bos; Baucke van Minnen
Journal:  Sci Rep       Date:  2020-10-23       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.