Literature DB >> 10868712

Comparable effects of inhaled fluticasone propionate and budesonide on the HPA-axis in adult asthmatic patients.

N Ringdal1, B Lundbäck, M Alton, S Rak, A Eivindson, G Bratten, P Kjaersgaard.   

Abstract

This randomized, double-blind, double-dummy, multicentre cross-over study compared the effects on the hypothalamic-pituitary-adrenal (HPA) axis of fluticasone propionate (750 microg twice daily given via the Diskus) and budesonide (800 microg twice daily given via the Turbuhaler). Two treatment periods of 2 weeks each were preceded by a 2-week run-in period and separated by a 2-week washout period. During run-in and washout, patients received beclomethasone dipropionate (BDP) or budesonide at a constant dose of 1500-1600 microg day(-1). Sixty patients aged 18-75 years with moderate to severe asthma not fully controlled by treatment with 1500-1600 microg day(-1) budesonide or BDP entered run-in and 45 completed the study. HPA axis suppression was assessed by morning serum cortisol (area under the curve from 08.00 to 10.30 hours) and 12-h nocturnal urinary cortisol excretion, measured at the end of run-in (baseline 1), at the end of washout (baseline 2), and at the end of each treatment period. Neither budesonide nor fluticasone produced significant suppression of either parameter compared to baselines. Only a few patients had serum-cortisol and urinary cortisol values below the normal range, before and after treatment. This shows that the patients did not have adrenal suppression before entering the study. The ratio between the AUC serum cortisol measured after fluticasone treatment and after budesonide treatment was 0.99 (95% CI 0.92-1.06), indicating equivalent effects on the HPA axis. This result was achieved after having omitted two patients' results, due to their very sensitive reaction to budesonide, but not to fluticasone. Two exacerbations of acute asthma occurred during budesonide treatment and none during fluticasone treatment. Both treatments were well tolerated. In conclusion, budesonide 1600 microg day(-1) via Turbuhaler and fluticasone propionate 1500 microg day(-1) via Diskus had no clinical effects on the HPA axis in patients with moderate to severe asthma.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10868712     DOI: 10.1053/rmed.1999.0758

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  3 in total

1.  Systemic activity of inhaled corticosteroid treatment in asthmatic children: corticotrophin releasing hormone test.

Authors:  L Pescollderungg; G Radetti; E Gottardi; D G Peroni; A Pietrobelli; A L Boner
Journal:  Thorax       Date:  2003-03       Impact factor: 9.139

Review 2.  Inhaled corticosteroids in the long-term management of patients with chronic obstructive pulmonary disease.

Authors:  Don D Sin; S F Paul Man
Journal:  Drugs Aging       Date:  2003       Impact factor: 3.923

3.  Comparison of the effect of high-dose inhaled budesonide and fluticasone on adrenal function in patients with severe chronic obstructive pulmonary disease.

Authors:  Ahmed Fahim; Shoaib Faruqi; Caroline E Wright; Jack A Kastelik; Alyn H Morice
Journal:  Ann Thorac Med       Date:  2012-07       Impact factor: 2.219

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.