Literature DB >> 10866916

Carbon dioxide absorbents containing potassium hydroxide produce much larger concentrations of compound A from sevoflurane in clinical practice.

M Yamakage1, S Yamada, X Chen, S Iwasaki, N Tsujiguchi, A Namiki.   

Abstract

UNLABELLED: We investigated the concentrations of degraded sevoflurane Compound A during low-flow anesthesia with four carbon dioxide (CO(2)) absorbents. The concentrations of Compound A, obtained from the inspiratory limb of the circle system, were measured by using a gas chromatograph. In the groups administered 2 L/min fresh gas flow with 1% sevoflurane, when the conventional CO(2) absorbents, Wakolime(TM) (Wako, Tokyo, Japan) and Drägersorb(TM) (Dräger, Lübeck, Germany), were used, the concentrations of Compound A increased steadily from a baseline to 14.3 ppm (mean) and 13.2 ppm, respectively, at 2 h after exposure to sevoflurane. In contrast, when the other novel types of absorbents containing decreased or no potassium hydroxide/sodium hydroxide, Medisorb(TM) (Datex-Ohmeda, Louisville, CO) and Amsorb(TM) (Armstrong, Coleraine, Northern Ireland), were used, Compound A remained at baseline (<2 ppm) throughout the study. In the groups administered 1 L/min fresh gas flow with 2% sevoflurane, Wakolime(TM) and Drägersorb(TM) produced much larger concentrations of Compound A (35.4 ppm and 34.2 ppm, respectively) at 2 h after exposure to sevoflurane. Medisorb(TM) showed measurable concentrations of Compound A (8.6 ppm at 2 h), but they were significantly smaller than those produced by the two conventional absorbents. In contrast, when Amsorb(TM) was used, Compound A concentrations remained at baseline throughout the study period. IMPLICATIONS: Carbon dioxide absorbents containing potassium hydroxide/sodium hydroxide produce much larger concentrations of Compound A from sevoflurane in clinical practice. An absorbent containing neither potassium hydroxide nor sodium hydroxide produces the smallest concentrations of Compound A.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10866916     DOI: 10.1097/00000539-200007000-00041

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  1 in total

1.  Comparison of the renal safety between carbon dioxide absorbent products under sevoflurane anesthesia: a pilot study.

Authors:  Hyung-Chul Lee; Donguk Kim; Wonsik Ahn; Jiyeon Sim; Yehoon Chung
Journal:  Korean J Anesthesiol       Date:  2012-07-24
  1 in total