Literature DB >> 10865733

Comparison of whole body and segmental bioimpedance methodologies for estimating total body water.

M J Wotton1, B J Thomas, B H Cornish, L C Ward.   

Abstract

We compared the whole body (WB) and segmental bioelectrical impedance analysis (BIA) methodologies in a group of healthy adults (n = 25). It has been suggested that the segmental methodology may overcome the difficulty in generating a single algorithm to predict total body water (TBW) in all groups whether healthy or not. We measured TBW, using D2O dilution, and WB and segmental BIA parameters. Cole-Cole analysis was used to determine the impedance at the characteristic frequency (Zc). The correlation between TBW (by D2O dilution) and segmental BIA measures (multiple regression, r = 0.90, p < 0.001, SEE = 3.1 L) was not significantly higher than the correlation between TBW (D2O dilution) and WB BIA measures (simple regression, r = 0.85, p < 0.001, SEE = 3.6 L). Others have observed this "lack of improvement" in a group of healthy subjects. The true value of the segmental BIA methodology may lie in applications involving groups with altered distributions of segmental and compartmental fluid.

Entities:  

Mesh:

Year:  2000        PMID: 10865733     DOI: 10.1111/j.1749-6632.2000.tb06444.x

Source DB:  PubMed          Journal:  Ann N Y Acad Sci        ISSN: 0077-8923            Impact factor:   5.691


  4 in total

1.  How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?

Authors:  Joan E Sanders; Daniel S Harrison; Katheryn J Allyn; Timothy R Myers; Marcia A Ciol; Elaine C Tsai
Journal:  J Rehabil Res Dev       Date:  2012

2.  Comparison of body fat-free masses calculated from hand-to-foot and foot-to-foot resistances with DXA measurements.

Authors:  Sana Bousbiat; Michel Y Jaffrin; Edwige Dongmo
Journal:  Med Biol Eng Comput       Date:  2011-09-14       Impact factor: 2.602

3.  Effects of elevated vacuum on in-socket residual limb fluid volume: case study results using bioimpedance analysis.

Authors:  Joan E Sanders; Daniel S Harrison; Timothy R Myers; Katheryn J Allyn
Journal:  J Rehabil Res Dev       Date:  2011

4.  A Bioimpedance Analysis Platform for Amputee Residual Limb Assessment.

Authors:  Joan E Sanders; Mark A Moehring; Travis M Rothlisberger; Reid H Phillips; Tyler Hartley; Colin R Dietrich; Christian B Redd; David W Gardner; John C Cagle
Journal:  IEEE Trans Biomed Eng       Date:  2015-11-19       Impact factor: 4.538

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.