Literature DB >> 10864282

Laplacian electrocardiography.

B He1, D Wu.   

Abstract

This article reviews the recent development in Laplacian electrocardiography. The Laplacian electrocardiogram was proposed in the early 1990s as an alternative for mapping regional cardiac electrical activity. Considerable progress has been made in the field during the last 5 years on this emerging technique. This article attempts to cover both the basic concepts and theory for general readers in biomedical engineering, and state-of-the-art developments in forward and inverse problems of Laplacian electrocardiography, as well as Laplacian ECG mapping in an experimental setting for researchers working in the field of cardiac mapping. The article also addresses controversies regarding the feasibility of experimentally obtaining the Laplacian electrocardiogram in human subjects. The work reviewed in this article suggests that Laplacian electrocardiography merits further investigation and promises to provide an important alternative means of assessing noninvasively cardiac electrical activity.

Entities:  

Mesh:

Year:  1999        PMID: 10864282

Source DB:  PubMed          Journal:  Crit Rev Biomed Eng        ISSN: 0278-940X


  8 in total

1.  Body surface Laplacian mapping of atrial depolarization in healthy human subjects.

Authors:  J Lian; G Li; J Cheng; B Avitall; B He
Journal:  Med Biol Eng Comput       Date:  2002-11       Impact factor: 2.602

2.  Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.

Authors:  Oleksandr Makeyev; Quan Ding; Walter G Besio
Journal:  Measurement (Lond)       Date:  2016-02-01       Impact factor: 3.927

3.  Localization of endocardial ectopic activity by means of noninvasive endocardial surface current density reconstruction.

Authors:  Dakun Lai; Chenguang Liu; Michael D Eggen; Paul A Iaizzo; Bin He
Journal:  Phys Med Biol       Date:  2011-06-21       Impact factor: 3.609

4.  Usefulness of ventricular endocardial electric reconstruction from body surface potential maps to noninvasively localize ventricular ectopic activity in patients.

Authors:  Dakun Lai; Jian Sun; Yigang Li; Bin He
Journal:  Phys Med Biol       Date:  2013-05-16       Impact factor: 3.609

5.  Comparison of electrohysterogram signal measured by surface electrodes with different designs: A computational study with dipole band and abdomen models.

Authors:  Pei Gao; Dongmei Hao; Yang An; Ying Wang; Qian Qiu; Lin Yang; Yimin Yang; Song Zhang; Xuwen Li; Dingchang Zheng
Journal:  Sci Rep       Date:  2017-12-11       Impact factor: 4.379

6.  Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes.

Authors:  Javier Garcia-Casado; Yiyao Ye-Lin; Gema Prats-Boluda; Oleksandr Makeyev
Journal:  Sensors (Basel)       Date:  2019-08-31       Impact factor: 3.576

7.  Evaluation of Swallowing Related Muscle Activity by Means of Concentric Ring Electrodes.

Authors:  J Garcia-Casado; G Prats-Boluda; Y Ye-Lin; S Restrepo-Agudelo; E Perez-Giraldo; A Orozco-Duque
Journal:  Sensors (Basel)       Date:  2020-09-15       Impact factor: 3.576

8.  Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.

Authors:  Oleksandr Makeyev; Walter G Besio
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.