Abstract

OBJECTIVE: The purpose of this paper was to investigate the fatigue strength of a hydrothermal ceramic fused to Ag-Pd alloy. This study compared the values with those of other metal-ceramic systems previously reported by other authors.
METHODS: This investigation was performed on 48 specimens made of Ag-Pd alloy frames (45 x 12 x 4 mm) on which the hydrothermal ceramic was fused (25 x 12 x 2 gmm). The specimens were divided into two groups. The first group of specimens was dynamically loaded immediately after casting and fusing, while the other group of specimens was thermocycled (1000 times at 0 degree C and 55 degrees C) before dynamic loading. The dynamic loading tests were carried out by using a modified three-point load method in a universal testing machine.
RESULTS: The determined dynamic loading limit was up to 550 N for thermocycled, and up to 850 N for non-thermocycled specimens. These results are very respectable in comparison with other metal-ceramics. A statistically significant difference between maximal dynamic forces and number of loading cycles for thermocycled and non-thermocycled samples was determined. SIGNIFICANCE: From the data obtained in this study and current literature profiles, it is concluded that the tested metal-ceramic system is more durable than other metal-ceramic systems.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10863442     DOI: 10.1016/s0109-5641(99)00068-8

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  2 in total

1.  Comparing two intraoral porcelain repair systems for shear bond strength in repaired cohesive and adhesive fractures, for porcelain-fused-to-metal restorations: An in vitro study.

Authors:  Jaiveer Singh Yadav; Nupur Dabas; Akshay Bhargava; Puja Malhotra; Bhupender Yadav; Manoti Sehgal
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10

2.  The Influence of Recycling on the Properties of Interface between Ceramic and Dental Alloys.

Authors:  Yinghui Wang; Honglan Huang; Honglei Lin; Lei Jiang; Yu Pan; Xiurong Li; Hui Cheng
Journal:  Biomed Res Int       Date:  2020-04-08       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.