Literature DB >> 10857654

Thin-film glucose biosensor based on plasma-polymerized film: simple design for mass production.

H Muguruma1, A Hiratsuka, I Karube.   

Abstract

We propose a simple thin-film glucose biosensor based on a plasma-polymerized film. The film is deposited directly onto the substrate under dry conditions. The resulting films are extreme thin, adhere well onto the substrate (electrode), and have a highly cross-linked network structure and functional groups, such as amino groups, which enable a large amount of enzyme to be immobilized. Since this design allows fabrication through a dry process, with the exception of the enzyme immobilization, which is the last stage of the process, the chip fabrication can be designed as a full-wafer process to achieve mass production compatibility. The resulting sensors produced using this film are more reproducible, exhibit lower noise, and reduce the effect of interference to a greater degree than sensors made using conventional immobilization methods, e.g., via 3-(aminopropyl)triethoxysilane. The obtained film is a good interfacial design between enzyme and electrode; enzyme two-dimensionally locates very close to the electrode in a manner that is quite reproducible. Therefore, a wide dynamic range (up to 60 mM) and rapid response time (11.5+/-0.8 s) were obtained. Because of its highly cross-linking network structure, the amperometric response due to interferences such as ascorbic acid and acetaminophen was reduced by size discrimination of plasma-polymerized films.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10857654     DOI: 10.1021/ac000014n

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Fabrication and Plasma Modification of Nanofibrous Tissue Engineering Scaffolds.

Authors:  Mahtab Asadian; Ke Vin Chan; Mohammad Norouzi; Silvia Grande; Pieter Cools; Rino Morent; Nathalie De Geyter
Journal:  Nanomaterials (Basel)       Date:  2020-01-08       Impact factor: 5.076

Review 2.  A comprehensive review of glucose biosensors based on nanostructured metal-oxides.

Authors:  Md Mahbubur Rahman; A J Saleh Ahammad; Joon-Hyung Jin; Sang Jung Ahn; Jae-Joon Lee
Journal:  Sensors (Basel)       Date:  2010-05-12       Impact factor: 3.576

3.  Enhancement of Fluorescence-Based Sandwich Immunoassay Using Multilayered Microplates Modified with Plasma-Polymerized Films.

Authors:  Kazuyoshi Yano; Akira Iwasaki
Journal:  Sensors (Basel)       Date:  2016-12-25       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.