Literature DB >> 10857651

Lab-on-a-Cable for electrochemical monitoring of phenolic contaminants.

J Wang1, J Lu, S Y Ly, M Vuki, B Tian, W K Adeniyi, R A Armendariz.   

Abstract

The "Lab-on-a-Cable" concept, based on scaling down an electrochemical flow system to a cable platform, is described. The system integrates the analyte collection and the sample handling, with the electrochemical detection of the reaction product in a sealed cylindrical unit, connected to a long shielded cable. An enzymatic assay, involving collection of a phenolic substrate, its mixing with an internally delivered tyrosinase solution, and amperometric detection of the liberated quinone product, is used for illustrating the operation of the flow probe and demonstrating its advantages over remote phenol sensors. The internal buffer solution ensures independence of sample conditions such as pH, ionic strength, or natural conditions, that commonly influences the performance of remote sensors. The "built-in" flow pulsation of the integrated micropump is exploited for a sensitive hydrodynamic-modulation voltammetric detection of hydrazine and peroxide pollutants.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10857651     DOI: 10.1021/ac991054y

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Voltammetric bioassay of caffeine using sensor implant.

Authors:  Suw Young Ly; Chang Hyun Lee; Young Sam Jung
Journal:  Neuromolecular Med       Date:  2009-01-01       Impact factor: 3.843

Review 2.  Nanomedicines for back of the eye drug delivery, gene delivery, and imaging.

Authors:  Uday B Kompella; Aniruddha C Amrite; Rashmi Pacha Ravi; Shelley A Durazo
Journal:  Prog Retin Eye Res       Date:  2013-04-17       Impact factor: 21.198

Review 3.  Microneedle-based drug delivery systems: microfabrication, drug delivery, and safety.

Authors:  Ryan F Donnelly; Thakur Raghu Raj Singh; A David Woolfson
Journal:  Drug Deliv       Date:  2010-05       Impact factor: 6.419

4.  Real-time Detection of Trace Copper in Brain and Kidney of Fish for Medical Diagnosis.

Authors:  Young Kyun Yang; Eun Chul Pack; Seung Ha Lee; Hai-Soo Yoo; Dal Woong Choi; Suw Young Ly
Journal:  Toxicol Res       Date:  2014-12

5.  Voltammetric Assay of Mercury Ion in Fish Kidneys.

Authors:  Suw Young Ly
Journal:  Toxicol Res       Date:  2008-03-01

6.  Assay of In Vivo Chromium with a Hollow-fiber Dialysis Sensor.

Authors:  Suw Young Ly; Hai-Soo Yoo; Minki Jung; Kwang Hee Ko; Byung Jin Kim; Ki Chul Lee; Byung Min Choi
Journal:  Toxicol Res       Date:  2010-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.