Literature DB >> 10854887

A new ambulatory foot pressure device for patients with sensory impairment. A system for continuous measurement of plantar pressure and a feed-back alarm.

Z Pataky1, L Faravel, J Da Silva, J Assal.   

Abstract

Abnormal and excessive plantar pressure is a major risk factor for the development of foot ulcers in patients with loss of protective pain sensation. Repeated pressure with each step can result in inflammation at specific points, followed by ulcer formation. Patients with peripheral nerve disease are unable to prevent the development of such lesions, which often lead to amputation. For this reason, it has been suggested that a fundamental therapeutic intervention should be the reduction of high plantar pressure. We have developed a portable, battery-operated ambulatory foot pressure device (AFPD) which has two important functions: (1) to determine the areas of high plantar pressure, and (2) to provide an acoustic alarm, adjusted to a specific pressure load, which is triggered when weight-bearing exceeds the predetermined plantar pressure. A memory of plantar pressure parameters allows for downloading of the data and sequential analysis during the investigation period. Such an alarm device could replace the lack of pain sensation and may play an important role in the prevention of ulcer development and lower extremity amputation.

Entities:  

Mesh:

Year:  2000        PMID: 10854887     DOI: 10.1016/s0021-9290(00)00082-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  A low-cost body inertial-sensing network for practical gait discrimination of hemiplegia patients.

Authors:  Yanwei Guo; Dan Wu; Guanzheng Liu; Guoru Zhao; Bangyu Huang; Lei Wang
Journal:  Telemed J E Health       Date:  2012-03-26       Impact factor: 3.536

Review 2.  Real-time human ambulation, activity, and physiological monitoring: taxonomy of issues, techniques, applications, challenges and limitations.

Authors:  Rinat Khusainov; Djamel Azzi; Ifeyinwa E Achumba; Sebastian D Bersch
Journal:  Sensors (Basel)       Date:  2013-09-25       Impact factor: 3.576

3.  Balance and knee extensibility evaluation of hemiplegic gait using an inertial body sensor network.

Authors:  Yanwei Guo; Guoru Zhao; Qianqian Liu; Zhanyong Mei; Kamen Ivanov; Lei Wang
Journal:  Biomed Eng Online       Date:  2013-08-29       Impact factor: 2.819

Review 4.  The role of foot pressure measurement in the prediction and prevention of diabetic foot ulceration-A comprehensive review.

Authors:  Katie E Chatwin; Caroline A Abbott; Andrew J M Boulton; Frank L Bowling; Neil D Reeves
Journal:  Diabetes Metab Res Rev       Date:  2019-12-11       Impact factor: 4.876

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.