Literature DB >> 10853906

Increased interleukin-8 (IL-8) expression is related to aseptic loosening of total hip replacement.

J Lassus1, V Waris, J W Xu, T F Li, J Hao, Y Nietosvaara, S Santavirta, Y T Konttinen.   

Abstract

Aseptic loosening is an increasing problem in total hip replacement (THR). Chronic inflammatory reaction against implant wear particle results in collageno- and osteolysis, leading to loosening of the implant. Cytokines are known to play a major role in this particular inflammatory process. The aim of the present study was to examine interleukin-8 (IL-8) in the synovial-like interface membrane (SLIM) and pseudocapsular tissue of THRs and to compare it to normal knee synovial membrane. Eleven patients suffering from aseptically loosened THRs were included. All the SLIM and pseudocapsular tissue samples were obtained during revision operations. Ten control samples of normal synovium were collected per arthroscopy from the superior recessus of the knee. For immunohistochemical IL-8 detection, polyclonal mouse anti-human immunoglobulin (Ig)G1 IL-8-primary antibody was used with the alkaline phosphatase anti-alkaline phosphatase (APAAP) method. Results were quantitated using the Vidas image analysis system. The highest count levels (mean +/- SEM) were detected in SLIM tissue (386+/-82 cells/mm2). The difference was statistically significant compared with pseudocapsular tissue (193+/-36 cells/mm2) and control samples (18+/-5 cells/mm2). Count levels in control tissue were on average 5% of the SLIM tissues values. The present study determines for the first time the cellular origin of IL-8 in aseptically loosened THRs and also quantitates the IL-8-producing cells in the periprosthetic tissue. The results reveal a high rise in IL-8 concentration in SLIM and in synovial tissues. This finding moves us one step forward in solving the complex network of multiple factors affecting loosening of hip implants.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10853906     DOI: 10.1007/s004020050475

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  16 in total

Review 1.  Mesenchymal stem cells in the aseptic loosening of total joint replacements.

Authors:  Jukka Pajarinen; Tzu-Hua Lin; Akira Nabeshima; Eemeli Jämsen; Laura Lu; Karthik Nathan; Zhenyu Yao; Stuart B Goodman
Journal:  J Biomed Mater Res A       Date:  2017-02-01       Impact factor: 4.396

2.  Innate immune reactions in septic and aseptic osteolysis around hip implants.

Authors:  Jukka Pajarinen; Eemeli Jamsen; Yrjo T Konttinen; Stuart B Goodman
Journal:  J Long Term Eff Med Implants       Date:  2014

3.  Biological responses of human mesenchymal stem cells to titanium wear debris particles.

Authors:  Hana Haleem-Smith; Evan Argintar; Curtis Bush; Daniel Hampton; William F Postma; Faye H Chen; Todd Rimington; Joshua Lamb; Rocky S Tuan
Journal:  J Orthop Res       Date:  2011-11-14       Impact factor: 3.494

4.  Focal osteolysis in total hip replacement: CT findings.

Authors:  Ji Seon Park; Kyung Nam Ryu; Hoon Pyo Hong; Yong Koo Park; Young Soo Chun; Myung Chul Yoo
Journal:  Skeletal Radiol       Date:  2004-07-31       Impact factor: 2.199

5.  Interaction of Materials and Biology in Total Joint Replacement - Successes, Challenges and Future Directions.

Authors:  J Pajarinen; T-H Lin; T Sato; Z Yao; S B Goodman
Journal:  J Mater Chem B       Date:  2014-11-07       Impact factor: 6.331

Review 6.  Novel biological strategies for treatment of wear particle-induced periprosthetic osteolysis of orthopaedic implants for joint replacement.

Authors:  S B Goodman; E Gibon; J Pajarinen; T-H Lin; M Keeney; P-G Ren; C Nich; Z Yao; K Egashira; F Yang; Y T Konttinen
Journal:  J R Soc Interface       Date:  2014-01-29       Impact factor: 4.118

Review 7.  How has the introduction of new bearing surfaces altered the biological reactions to byproducts of wear and modularity?

Authors:  Paul H Wooley
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

8.  The central role of wear debris in periprosthetic osteolysis.

Authors:  P Edward Purdue; Panagiotis Koulouvaris; Bryan J Nestor; Thomas P Sculco
Journal:  HSS J       Date:  2006-09

Review 9.  The role of TLR and chemokine in wear particle-induced aseptic loosening.

Authors:  Qiaoli Gu; Qin Shi; Huilin Yang
Journal:  J Biomed Biotechnol       Date:  2012-10-21

10.  Long-term results of cementless hip arthroplasty with ceramic-on-ceramic articulation.

Authors:  Marek Synder; Marek Drobniewski; Marcin Sibiński
Journal:  Int Orthop       Date:  2012-08-19       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.