Capability of respirator wearers to detect aerosolized qualitative fit test agents (sweetener and Bitrex) with known fixed leaks.

R T McKay1, E Davies.   

Abstract

This study was designed to evaluate and compare the ability of respirator wearers to detect qualitative respirator fit test agents (saccharin and Bitrex) when the respirators were modified to include fixed size leaks. In recent years the number of persons who require fit testing has increased, partly in response to the needs of health care workers with potential exposure to infectious bio-aerosols. Many health care providers have chosen qualitative respirator fit testing using saccharin and/or Bitrex for a variety of reasons, including (but not limited to) low initial equipment cost. Respirators were modified to include a mid-line sampling probe between the nose and mouth for quantitative fit testing with a TSI PortaCount. A second modification included the introduction of a shortened 14-gauge intravenous catheter at the bridge of the nose. The fixed leak was designed to produce fit factors < 100 when unplugged, with an average fit factor of 67 among 26 respirator wearers. A complete fit test was not performed, because one purpose of this study was to determine the ability of respirator wearers to detect a known fixed leak during a single normal breathing exercise, without introducing unknown and potentially variable size leaks. Sensitivity threshold screening included a placebo and requirement to correctly characterize the taste of the agent used. Quantitative fit factors without leaks ranged from 96 to > 20,000 and 22 to 160 with the leak present. Twenty four of 26 subjects had fit factors < 100 (92%) when fixed leaks were induced. All subjects correctly detected Bitrex with fixed leaks (sensitivity = 100%). Nine of 26 subjects (35%) were unable to detect saccharin in the presence of a known fixed leak even though the average fit factor for these subjects was 77. When the two subjects with fit factors > 100 were excluded, only 16 of 24 respirator wearers were able to detect saccharin with fixed leaks (sensitivity = 67%). There were several important aspects of our study design worth noting, including the introduction of a placebo during sensitivity threshold testing, limiting the subject response time to a single maneuver, using a higher concentration of Bitrex than commercially available, and requiring the subjects to correctly characterize the taste of the qualitative test agent. In conclusion, leak detection was correctly identified with Bitrex, but not saccharin.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10853288     DOI: 10.1080/104732200301269

Source DB:  PubMed          Journal:  Appl Occup Environ Hyg        ISSN: 1047-322X


  6 in total

1.  Qualitative fitting characteristics of filtering face-piece respirators on Iranian people.

Authors:  Anahita Fakherpour; Mehdi Jahangiri; Mozhgan Seif
Journal:  J Environ Health Sci Eng       Date:  2020-05-26

2.  [Masks as personal protective equipment in the COVID-19 pandemic: How, when and which should be used].

Authors:  Jesús M Aranaz Andrés; M Teresa Gea Velázquez de Castro; Jorge Vicente-Guijarro; Joaquín Beltrán Peribáñez; Mercedes García Haro; José Lorenzo Valencia-Martín; Cornelia Bischofberger Valdés
Journal:  J Healthc Qual Res       Date:  2020-06-25

3.  Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study.

Authors:  James D Byrne; Adam J Wentworth; Peter R Chai; Hen-Wei Huang; Sahab Babaee; Canchen Li; Sarah L Becker; Caitlynn Tov; Seokkee Min; Giovanni Traverso
Journal:  BMJ Open       Date:  2020-07-07       Impact factor: 2.692

4.  Prospective Evaluation of the Transparent, Elastomeric, Adaptable, Long-Lasting (TEAL) Respirator.

Authors:  Adam J Wentworth; James D Byrne; Sirma Orguc; Joanna Sands; Saurav Maji; Caitlynn Tov; Sahab Babaee; Hen-Wei Huang; Hannah Boyce; Peter R Chai; Seokkee Min; Canchen Li; Jacqueline N Chu; Avik Som; Sarah L Becker; Manish Gala; Anantha Chandrakasan; Giovanni Traverso
Journal:  ACS Pharmacol Transl Sci       Date:  2020-11-10

Review 5.  Respiratory protection against bioaerosols: literature review and research needs.

Authors:  Appavoo Rengasamy; Ziqing Zhuang; Roland Berryann
Journal:  Am J Infect Control       Date:  2004-10       Impact factor: 2.918

6.  Experimental Measurement of the Size of Gaps Required to Compromise Fit of an N95 Respirator.

Authors:  Eugenia O'Kelly; Anmol Arora; Sophia Pirog; James Ward; P John Clarkson
Journal:  Disaster Med Public Health Prep       Date:  2022-01-21       Impact factor: 1.385