Literature DB >> 10853182

The effects of conformity and load in total knee replacement.

M S Kuster1, S Horz, E Spalinger, G W Stachowiak, A Gächter.   

Abstract

The effects of different conformity ratios and loads on the ultrahigh molecular weight polyethylene stress levels acting on knee implants were examined using a nonlinear, finite element analysis. The contact condition between a rigid cylinder with a radius of 30 mm and a polyethylene plate was modeled. Nonlinear behavior of polyethylene was assumed. The polyethylene plate was constructed with varying radii, with a minimal thickness of 6 mm and with a width of 40 mm. The ratio of the cylinder radius to the radius of the polyethylene plate was defined as the conformity ratio; a conformity ratio of 0 represented a flat tibial inlay, whereas the highest ratio modeled of 0.99 was nearly conforming. The conformity ratios modeled were 0, 0.2, 0.4, 0.6, 0.7, 0.8, 0.9, 0.95, and 0.99. The loads applied were 1000 N, 2000 N, 3000 N, 4000 N, 5000 N, and 6000 N. The effects of different conformity ratios and loads on the contact area (mm2), the compressive surface stress (MPa), the shear stress (MPa), and the von Mises stress (MPa) were investigated. It was found that all of these parameters were affected by changes to the conformity ratio and to a lesser extent by load changes. That is, increasing the load from 3000 N to 6000 N resulted in a surface and shear stress increase lower than the increase in stress caused by the small change of the conformity ratio from 0.99 to 0.95. The effect of an increasing conformity ratio on the reduction in stress was more pronounced for conformity ratios above 0.8. In addition, the effect of a load increase for a flat tibial inlay was two times greater than for one with near full conformity.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10853182     DOI: 10.1097/00003086-200006000-00036

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Rotating-platform has no surface damage advantage over fixed-bearing TKA.

Authors:  Kirsten Stoner; Seth A Jerabek; Stephanie Tow; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

Review 2.  Exercise recommendations after total joint replacement: a review of the current literature and proposal of scientifically based guidelines.

Authors:  Markus S Kuster
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

3.  SPORTS ACTIVITY AND HIP, KNEE, SHOULDER AND INTERVERTEBRAL DISC ARTHROPLASTIES.

Authors:  Diogo Lino Moura; Fernando Pereira Fonseca
Journal:  Acta Ortop Bras       Date:  2018       Impact factor: 0.513

4.  Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation.

Authors:  S Key; G Scott; J G Stammers; M A R Freeman; V Pinskerova; R E Field; J Skinner; S A Banks
Journal:  Bone Joint Res       Date:  2019-06-05       Impact factor: 5.853

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.