Literature DB >> 10853063

Frameless stereotactic neurosurgery: two steps towards the Holy Grail of surgical navigation.

M S Eljamel1.   

Abstract

The holy grail of surgical navigation is to provide precise continuous feedback during surgery about the target and its surrounding structures. The first step was the ability of hardware and software technology to allow patient-to-image registration using a multi-potentiometer position-sensing articulated arm system. We used such a system (OAS; Radionics, Burlington, Mass., USA) in 169 consecutive patients with common intracranial lesions. We achieved a mean application accuracy of 2.5 mm, which was sufficiently reliable for most neurosurgical procedures. However, to get the feedback information, the surgeon has to look away from the operative field to the workstation monitor. As psychological studies of manual workers including surgeons indicated that performance is better when the worker is looking in a downward gaze at his hands, the natural progression was to project feedback information between the eyes and the hands. Therefore, the second step was to link tracking technology to the surgical microscope with head-up display. We used such a system (SMN-Zeiss, Germany) in 65 consecutive patients with a mean application accuracy of 1.4 mm. This was again sufficiently reliable for neuronavigation. The head-up display provided continuous feedback to the surgeon about the target, risk zones and areas of interest without the need to interrupt the procedure to get such information. Furthermore, the use of the focal length of SMN with autofocus to perform the registration improved the application accuracy of this technology. The ability of the software to process all MRI sequences (T(1), T(2), MPR and CISS) allowed us to use a variety of image sequences to delineate the lesion more exquisitely. Copyright 2000 S. Karger AG, Basel

Entities:  

Mesh:

Year:  1999        PMID: 10853063     DOI: 10.1159/000029711

Source DB:  PubMed          Journal:  Stereotact Funct Neurosurg        ISSN: 1011-6125            Impact factor:   1.875


  3 in total

1.  Use of neuronavigation and electrophysiology in surgery of subcortically located lesions in the sensorimotor strip.

Authors:  W Eisner; J Burtscher; R Bale; R Sweeney; F Koppelstätter; S Golaszewski; C Kolbitsch; K Twerdy
Journal:  J Neurol Neurosurg Psychiatry       Date:  2002-03       Impact factor: 10.154

2.  Perspectives and limitations of image-guided neurosurgery in pediatric patients.

Authors:  Vassilios I Vougioukas; Ulrich Hubbe; Albrecht Hochmuth; Nils C Gellrich; Vera van Velthoven
Journal:  Childs Nerv Syst       Date:  2003-10-11       Impact factor: 1.475

3.  Localization and registration accuracy in image guided neurosurgery: a clinical study.

Authors:  Reuben R Shamir; Leo Joskowicz; Sergey Spektor; Yigal Shoshan
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-10-28       Impact factor: 2.924

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.