Literature DB >> 10851810

Optimal digital filtering for tremor suppression.

J G Gonzalez1, E A Heredia, T Rahman, K E Barner, G R Arce.   

Abstract

Remote manually operated tasks such as those found in teleoperation, virtual reality, or joystick-based computer access, require the generation of an intermediate electrical signal which is transmitted to the controlled subsystem (robot arm, virtual environment, or a cursor in a computer screen). When human movements are distorted, for instance, by tremor, performance can be improved by digitally filtering the intermediate signal before it reaches the controlled device. This paper introduces a novel tremor filtering framework in which digital equalizers are optimally designed through pursuit tracking task experiments. Due to inherent properties of the man-machine system, the design of tremor suppression equalizers presents two serious problems: 1) performance criteria leading to optimizations that minimize mean-squared error are not efficient for tremor elimination and 2) movement signals show ill-conditioned autocorrelation matrices, which often result in useless or unstable solutions. To address these problems, a new performance indicator in the context of tremor is introduced, and the optimal equalizer according to this new criterion is developed. Ill-conditioning of the autocorrelation matrix is overcome using a novel method which we call pulled-optimization. Experiments performed with artificially induced vibrations and a subject with Parkinson's disease show significant improvement in performance. Additional results, along with MATLAB source code of the algorithms, and a customizable demo for PC joysticks, are available on the Internet at http:¿tremor-suppression.com.

Entities:  

Mesh:

Year:  2000        PMID: 10851810     DOI: 10.1109/10.841338

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  Real-time estimation of pathological tremor parameters from gyroscope data.

Authors:  Juan A Gallego; Eduardo Rocon; Javier O Roa; Juan C Moreno; José L Pons
Journal:  Sensors (Basel)       Date:  2010-03-16       Impact factor: 3.576

2.  Estimation of physiological tremor from accelerometers for real-time applications.

Authors:  Kalyana C Veluvolu; Wei Tech Ang
Journal:  Sensors (Basel)       Date:  2011-03-07       Impact factor: 3.576

3.  Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression.

Authors:  Gil Herrnstadt; Carlo Menon
Journal:  Front Bioeng Biotechnol       Date:  2016-03-31
  3 in total