Literature DB >> 10850465

Corneal wave aberration from videokeratography: accuracy and limitations of the procedure.

A Guirao1, P Artal.   

Abstract

A procedure to calculate the wave aberration of the human cornea from its surface shape measured by videokeratography is presented. The wave aberration was calculated as the difference in optical path between the marginal rays and the chief ray refracted at the surface, for both on- and off-axis objects. The corneal shape elevation map was obtained from videokeratography and fitted to a Zernike polynomial expansion through a Gram-Schmidt orthogonalization. The wave aberration was obtained also as a Zernike polynomial representation. The accuracy of the procedure was analyzed. For calibrated reference surface elevations, a root-mean-square error (RMSE) of 1 to 2 microm for an aperture 4-6 mm in diameter was obtained, and the RMSE associated with the experimental errors and with the fitting method was 0.2 microm. The procedure permits estimation of the corneal wave aberration from videokeratoscopic data with an accuracy of 0.05-0.2 microm for a pupil 4-6 mm in diameter, rendering the method adequate for many applications.

Entities:  

Mesh:

Year:  2000        PMID: 10850465     DOI: 10.1364/josaa.17.000955

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  18 in total

1.  Wave aberrations of the isolated crystalline lens.

Authors:  Austin Roorda; Adrian Glasser
Journal:  J Vis       Date:  2003-04-16       Impact factor: 2.240

2.  Contact lenses and special back surface design after penetrating keratoplasty to improve contact lens fit and visual outcome.

Authors:  C Gruenauer-Kloevekorn; U Kloevekorn-Fischer; G I W Duncker
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

Review 3.  Optical quality of the diabetic eye: a review.

Authors:  A M Calvo-Maroto; R J Perez-Cambrodí; C Albarán-Diego; A Pons; A Cerviño
Journal:  Eye (Lond)       Date:  2014-08-15       Impact factor: 3.775

4.  Corneal spherical aberration in Saudi population.

Authors:  Tarfah M Al-Sayyari; Samah M Fawzy; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2014-03-18

5.  Inverse optical design of the human eye using likelihood methods and wavefront sensing.

Authors:  Julia A Sakamoto; Harrison H Barrett; Alexander V Goncharov
Journal:  Opt Express       Date:  2008-01-07       Impact factor: 3.894

6.  Posterior corneal aberrations and their compensation effects on anterior corneal aberrations in keratoconic eyes.

Authors:  Minghan Chen; Geunyoung Yoon
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-07-18       Impact factor: 4.799

7.  Monochromatic higher order aberrations in highly myopic eyes with Staphyloma.

Authors:  Santiago Delgado-Tirado; Alberto López-Miguel; Yazmin Báez-Peralta; Lucía González-Buendía; Itziar Fernández; Jorge L Alió; Miguel J Maldonado; Rosa M Coco-Martín
Journal:  BMC Ophthalmol       Date:  2021-05-18       Impact factor: 2.209

8.  Customized eye models for determining optimized intraocular lenses power.

Authors:  Carmen Canovas; Pablo Artal
Journal:  Biomed Opt Express       Date:  2011-05-20       Impact factor: 3.732

9.  Centration axis in refractive surgery.

Authors:  Samuel Arba Mosquera; Shwetabh Verma; Colm McAlinden
Journal:  Eye Vis (Lond)       Date:  2015-02-24

10.  Factors associated with corneal high-order aberrations before and after femtosecond laser-assisted in situ keratomileusis.

Authors:  Jun Zeng; Gongpu Lan; Min Zhu; Kai Sun; Qun Shi; Guoqing Ma; Quan Liu
Journal:  Ann Transl Med       Date:  2021-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.