Literature DB >> 10847954

Investigations into the sterility of manually assembled extracorporeal circuits with vented reservoirs.

B Searles1, C E O'Leary, D Pettit, S Alexander, A Picone.   

Abstract

This study was designed to investigate the ability of an extracorporeal circuit (ECC) with a vented hard shell reservoir to remain sterile for a period of 72 h under dry conditions. The study was conducted in three phases. In Phase One: Two previously published methods for detecting contamination of the ECC were compared. A group of positive controls was collected by contaminating identical circuits with a known level of Enterobacter cloacae (ATTC: 13047) before initiating a regimen of "sample-dilute-sample" culturing. Negative controls for this phase were conducted by randomly sampling 1 L per manufacturer's lot of lactated ringers with each detection method. Culture results suggest that large volume filtration, but not small aliquot sampling, is sensitive to extremely low levels of contamination. No growth was detected in any negative control samples. In Phase Two: 19 ECC consisting of a membrane oxygenator, vented hardshell reservoir, arterial filter, and PVC tubing were removed from their sterile packages, assembled, and left unprotected in the moderate traffic environment of a research laboratory. The circuits were then primed with Lactated Ringer's solution. The prime solution was sampled for aerobic contamination by large volume filtration. None of the 19 samples detected contamination. In Phase Three: 43 ECC identical to the Phase Two circuits were assembled and left unprotected in the substerile pump room. The circuits were then primed, circulated, and cultured as in Phase Two. One of the 43 samples was discarded because of a recognized break in aseptic technique during sample collection. None of the remaining samples detected contamination. Mathematical calculations of binomial probabilities suggest that the chance of an open ECC developing a detectable level of contamination within 72 h of its dry assembly is insignificant.

Entities:  

Mesh:

Year:  1999        PMID: 10847954

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  1 in total

1.  Sterility Duration of Preprimed Extracorporeal Membrane Oxygenation Circuits.

Authors:  Vi Ean Tan; Alan T Evangelista; Dominick M Carella; Daniel Marino; Wayne S Moore; Nadji Gilliam; Arun Chopra; Jeffrey J Cies
Journal:  J Pediatr Pharmacol Ther       Date:  2018 Jul-Aug
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.