Literature DB >> 10847619

A ganglioside-based assay for cholera toxin using an array biosensor.

C A Rowe-Taitt1, J J Cras, C H Patterson, J P Golden, F S Ligler.   

Abstract

A rapid assay for cholera toxin (CT) has been developed using a fluorescence-based biosensor. This sensor was capable of analyzing six samples simultaneously for CT in 20 min with few manipulations required by the operator. The biochemical assays utilized a ganglioside-"capture" format: ganglioside GM1, utilized for capture of analyte, was immobilized in discrete locations on the surface of the optical waveguide. Binding of CT to immobilized GM1 was demonstrated with direct assays (using fluorescently labeled CT) and "sandwich" immunoassays (using fluorescently labeled tracer antibodies). Limits of detection for CT were 200 ng/ml in direct assays and 40 ng/ml and 1 microg/ml in sandwich-type assays performed using rabbit and goat tracer antibodies. Binding of CT to other glycolipid capture reagents was also observed. While significant CT binding was observed to loci patterned with GD1b, Gb3, and Gb4, CT did not bind significantly to immobilized GT1b at the concentrations tested. This is the first description of such a non-antibody-based recognition system in a multi-specific planar array sensor.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10847619     DOI: 10.1006/abio.2000.4571

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

1.  A portable array biosensor for detecting multiple analytes in complex samples.

Authors:  C R Taitt; J P Golden; Y S Shubin; L C Shriver-Lake; K E Sapsford; A Rasooly; F S Ligler
Journal:  Microb Ecol       Date:  2004-02-09       Impact factor: 4.552

2.  Identification of molecular-mimicry-based ligands for cholera diagnostics using magnetic relaxation.

Authors:  Charalambos Kaittanis; Tuhina Banerjee; Santimukul Santra; Oscar J Santiesteban; Ken Teter; J Manuel Perez
Journal:  Bioconjug Chem       Date:  2011-01-12       Impact factor: 4.774

3.  Detection of bacterial toxins with monosaccharide arrays.

Authors:  Miriam M Ngundi; Chris R Taitt; Scott A McMurry; Daniel Kahne; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2005-06-08       Impact factor: 10.618

4.  Detection of Salmonella enterica serovar typhimurium by using a rapid, array-based immunosensor.

Authors:  Chris Rowe Taitt; Yura S Shubin; Roselina Angel; Frances S Ligler
Journal:  Appl Environ Microbiol       Date:  2004-01       Impact factor: 4.792

Review 5.  Array Biosensor for Toxin Detection: Continued Advances.

Authors:  Chris Rowe Taitt; Lisa C Shriver-Lake; Miriam M Ngundi; Frances S Ligler
Journal:  Sensors (Basel)       Date:  2008-12-15       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.