Literature DB >> 1084709

[Experimental ultrasonography of the rabbit eye (author's transl)].

H Freyler, H Arnfelser, H Weiss.   

Abstract

In 20 adult rabbits of the Gelbsilber-strain the axial depth of the anterior chamber, the axial thickness of the lens, and 7 different diameters of the vitreous chamber were measured by means of bioechometry for standardization of the to date neglected experimental ultrasonography of animal eyes. For proper interpretation of echograms of the rabbit eye the particular anatomy and topography of the lens must be considered. Penetration of the large and almost spherical lens by the beam can only be avoided if the probe is placed behind the limbus or behind the equator of the globe. In the axial ultrasonogram the high single peaked echo of the posterior lens capsule appears between the third and fourth fifth of the entire axial length. In all other types of echogram the beam passes through peripheral sections of the lens oblique, and produces several small echoes, thus eventually simulating a pathologic echogram of the vitreous body.

Entities:  

Mesh:

Year:  1976        PMID: 1084709     DOI: 10.1007/bf00417297

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  7 in total

1.  Changes in the depth of the anterior chamber and in the radius of curvature of the front surface of the lens during growth. Observations on the rabbit.

Authors:  A SORSBY; J STONE; G A LEARY; M SHERIDAN
Journal:  Br J Ophthalmol       Date:  1960-08       Impact factor: 4.638

2.  The effects of nonabsorbable intrascleral sutures on the growing albino rabbit eye.

Authors:  R E LAND
Journal:  Am J Ophthalmol       Date:  1957-04       Impact factor: 5.258

3.  The Anatomy and Histology of the Eye and Orbit of the Rabbit.

Authors:  F A Davis
Journal:  Trans Am Ophthalmol Soc       Date:  1929

4.  [Echography of experimentally provoked vitreous membranes. A trial of standardization (author's transl)].

Authors:  H Freyler; H Weiss; B Kosmath
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1974

5.  Oculopression. (Types and methods of application, possibilities of utilisation).

Authors:  D Vörösmarthy
Journal:  Bibl Ophthalmol       Date:  1966

6.  [Ultra-sound echography--an important auxiliary examination in the surgery of retinal detachment].

Authors:  H Freyler
Journal:  Klin Monbl Augenheilkd       Date:  1970-11       Impact factor: 0.700

7.  [The pathway of ultrasound in the eye and its clinical aspects].

Authors:  A Oksala
Journal:  Klin Monbl Augenheilkd       Date:  1967-04       Impact factor: 0.700

  7 in total