Literature DB >> 10845486

Time-resolved contrast-enhanced MR angiography of renal artery stenosis: diagnostic accuracy and interobserver variability.

M Völk1, M Strotzer, M Lenhart, C Manke, W R Nitz, J Seitz, S Feuerbach, J Link.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate diagnostic accuracy and interobserver variability of time-resolved three-dimensional gadolinium-enhanced MR angiography in the detection of renal artery stenosis in comparison with intraarterial digital subtraction angiography as the standard of reference. SUBJECTS AND METHODS: Forty consecutive patients (age range, 25-81 years; mean, 62.9 +/- 11.9 years) with suspected renal artery stenosis underwent intraarterial digital subtraction angiography and gadolinium-enhanced MR angiography, performed on a 1.5-T system with fast low-angle shot three-dimensional imaging (3.8/1.49 [TR/TE], 25 degrees flip angle, 10-sec acquisition time, and 1.5-mm partition thickness). Three time-resolved phases were obtained in a single breath-hold. Digital subtraction angiography and gadolinium-enhanced MR angiography were evaluated by four observers who studied 80 main renal arteries and 19 accessory vessels to evaluate the degree of stenosis. A stenosis reducing the intraarterial diameter by more than 50% was regarded as hemodynamically significant. Interobserver variability was calculated.
RESULTS: Only one gadolinium-enhanced MR angiography study was not of diagnostic quality, as a result of failure of the power injector. All main branches were of diagnostic quality in 38 (97.4%) of the remaining 39 gadolinium-enhanced MR angiography studies. Seventeen (89.5%) of 19 accessory renal arteries were depicted with gadolinium-enhanced MR angiography. The overall sensitivity for significant stenoses was 92.9%. The overall specificity was 83.4%, and the overall accuracy was 85.9%. Interobserver variability of gadolinium-enhanced MR angiography exceeded that of digital subtraction angiography.
CONCLUSION: Time-resolved three-dimensional gadolinium-enhanced MR angiography is a useful noninvasive method of screening suspected renal artery stenosis because of its easy application, short examination time, and high sensitivity despite of its higher interobserver variability.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10845486     DOI: 10.2214/ajr.174.6.1741583

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  MR-velocity mapping in vascular stents to assess peak systolic velocity. In vitro comparison of various stent designs made of Stainless Steel and Nitinol.

Authors:  Jacqueline van Holten; Patrik Kunz; Paul G H Mulder; Peter M T Pattynama; Hildo J Lamb; Lukas C van Dijk
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Contrast-bolus MR angiography of the transplanted kidney with a low-field (0.5-T) scanner: diagnostic accuracy, sensitivity and specificity of images and reconstructions in the evaluation of vascular complications.

Authors:  A Stecco; P Oronzo; F Armienti; C Borraccino; R Fossaceca; L Canalis; A Carriero
Journal:  Radiol Med       Date:  2007-10-21       Impact factor: 3.469

3.  New onset hypertension-rare intimal variant fibromuscular dysplasia.

Authors:  Jagadeesh K Kalavakunta; Hemasri Tokala; Vishal Gupta
Journal:  J Cardiol Cases       Date:  2011-07-21

4.  Renal artery stenosis: comparative evaluation of gadolinium-enhanced MRA and DSA.

Authors:  F Stacul; S Gava; M Belgrano; S Cernic; L Pagnan; F Pozzi Mucelli; M A Cova
Journal:  Radiol Med       Date:  2008-05-15       Impact factor: 3.469

5.  Time-resolved contrast-enhanced MR angiography: Value of hemodynamic information in the assessment of vascular diseases.

Authors:  Edyta Maj; Andrzej Cieszanowski; Olgierd Rowiński; Mikołaj Wojtaszek; Małgorzata Szostek; Robert Tworus
Journal:  Pol J Radiol       Date:  2010-01

6.  Fibromuscular dysplasia in an accessory renal artery causing renovascular hypertension: a case report.

Authors:  Abdel-Rauf Zeina; Wolfson Vladimir; Elisha Barmeir
Journal:  J Med Case Rep       Date:  2007-07-31

7.  Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study.

Authors:  Yigang Pei; Fang Li; Hao Shen; Xueying Long; Hui Liu; Xiaoyi Wang; Jinkang Liu; Wenzheng Li
Journal:  Korean J Radiol       Date:  2016-01-06       Impact factor: 3.500

  7 in total