Literature DB >> 10842461

Improved health after intervention in a school with moisture problems.

M Ahman1, A Lundin, V Musabasić, E Söderman.   

Abstract

In a school with floor moisture problems, the personnel had complaints consistent with the sick-building syndrome (SBS). Interventive measures including the laying of a ventilated floor were undertaken to eliminate the emissions. To examine if the intervention resulted in positive health effects, 34 personnel and 336 pupils were interviewed just before the intervention and also 7 months after. Also were interviewed 21 personnel and 224 pupils at an adjacent school serving as a control. Compared with the control school, the problem school showed more complaints, more general symptoms and more symptoms from the eyes, airways and skin, both among the personnel and the pupils. In the post-intervention examinations, the excess of symptoms among the personnel had almost disappeared. Among the pupils, the frequency of eye irritation was reduced but a general improvement of the other symptoms was not as obvious. However, after adjustment for a recent common cold, atopy and stress among the pupils, only one symptom ("stuffy nose") remained significantly elevated. In conclusion, the intervention was followed by positive health effects, supporting the hypothesis that emissions from building material had contributed to the excess of symptoms. A recent common cold was highly related to the symptoms and should be considered in future SBS studies.

Entities:  

Mesh:

Year:  2000        PMID: 10842461     DOI: 10.1034/j.1600-0668.2000.010001057.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  6 in total

Review 1.  Remediating buildings damaged by dampness and mould for preventing or reducing respiratory tract symptoms, infections and asthma.

Authors:  Riitta Sauni; Jos H Verbeek; Jukka Uitti; Merja Jauhiainen; Kathleen Kreiss; Torben Sigsgaard
Journal:  Cochrane Database Syst Rev       Date:  2015-02-25

2.  Medical and social prognoses of non-specific building-related symptoms (Sick Building Syndrome): a follow-up study of patients previously referred to hospital.

Authors:  B Edvardsson; B Stenberg; J Bergdahl; N Eriksson; G Lindén; L Widman
Journal:  Int Arch Occup Environ Health       Date:  2007-10-09       Impact factor: 3.015

Review 3.  Indoor mold, toxigenic fungi, and Stachybotrys chartarum: infectious disease perspective.

Authors:  D M Kuhn; M A Ghannoum
Journal:  Clin Microbiol Rev       Date:  2003-01       Impact factor: 26.132

4.  A longitudinal study of sick building syndrome (SBS) among pupils in relation to SO2, NO2, O3 and PM10 in schools in China.

Authors:  Xin Zhang; Fan Li; Li Zhang; Zhuohui Zhao; Dan Norback
Journal:  PLoS One       Date:  2014-11-14       Impact factor: 3.240

5.  Sick Building Syndrome Among Junior High School Students in Japan in Relation to the Home and School Environment.

Authors:  Motoko Takaoka; Kyoko Suzuki; Dan Norbäck
Journal:  Glob J Health Sci       Date:  2015-06-12

6.  Associations between indoor environmental quality in schools and symptom reporting in pupil-administered questionnaires.

Authors:  Kateryna Savelieva; Tero Marttila; Jussi Lampi; Sari Ung-Lanki; Marko Elovainio; Juha Pekkanen
Journal:  Environ Health       Date:  2019-12-27       Impact factor: 5.984

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.