Literature DB >> 10842148

Arm vein conduit is superior to composite prosthetic-autogenous grafts in lower extremity revascularization.

P L Faries1, F W Logerfo, S Arora, M C Pulling, D I Rohan, C M Akbari, D R Campbell, G W Gibbons, F B Pomposelli.   

Abstract

PURPOSE: Various alternative conduits have been used for lower extremity revascularization when an adequate ipsilateral greater saphenous vein is absent. This study compared the effectiveness of all-autogenous multisegment arm vein bypass grafts with that of composite grafts composed of combined prosthetic and autogenous conduits.
METHODS: One hundred fifty-three lower extremity revascularization procedures performed between 1990 and 1998 were followed up prospectively using a computerized vascular registry. The grafts were composed of spliced arm vein segments with venovenostomy in 122 and of composite prosthetic-autogenous conduit in 31. Arm vein conduit was prepared by means of intraoperative angioscopy for valve lysis and identification of luminal abnormalities in 47.7% of cases.
RESULTS: Bypass graft configurations were as follows: femoropopliteal (12 arm vein, 2 composite); femorotibial (75 arm vein, 23 composite); femoropedal (14 arm vein, 6 composite), and popliteo-tibial/pedal (21 arm vein, 0 composite). The indication for surgery was limb salvage in 98% and disabling claudication in 2% of cases. The mean follow-up was 25.1 months (range, 1 month to 7.9 years). Overall survival at 4 years was 51%. Overall patency and limb salvage rates were as follows: primary patency, at 1 year-arm vein, 76.9% +/- 4.8%; composite, 59. 5% +/- 9.6% (P =.02); at 3 years-arm vein, 70.0% +/- 8.0%; composite, 43.7% +/- 12.4% (P <.01); and at 5 years-arm vein, 53.8% +/- 8.7%; composite, 0%; secondary patency, at 1 year-arm vein, 77.5% +/- 4. 6%; composite, 59.8% +/- 9.5% (P =.02); at 3 years-arm vein, 70.7% +/- 7.5%, composite, 44.9% +/- 13.1% (P <.01); at 5 years-arm vein, 57.7% +/- 8.0%; composite, 0%; limb salvage, at 1 year-arm vein, 89. 3% +/- 3.7%; composite, 73.9% +/- 8.9% (P <.01); at 3 years-arm vein, 80.5% +/- 7.0%; composite, 49.6% +/- 14.3% (P <.01); at 5 years-arm vein, 76.3% +/- 9.9%; composite, 0%.
CONCLUSION: In this study, multisegment autogenous arm vein was used successfully in a wide variety of lower extremity revascularization procedures and achieved good long-term patency and limb salvage rates, well in excess of those achieved with composite prosthetic-autogenous grafts. The use of autogenous conduit appears to offer superior results to composite conduit in lower extremity revascularization. The superior durability of arm vein makes it one of the alternative conduits of choice when an adequate greater saphenous vein is not available.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10842148     DOI: 10.1067/mva.2000.106488

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

Review 1.  Engineering of bypass conduits to improve patency.

Authors:  S T Rashid; H J Salacinski; B J Fuller; G Hamilton; A M Seifalian
Journal:  Cell Prolif       Date:  2004-10       Impact factor: 6.831

2.  Platform technologies for decellularization, tunic-specific cell seeding, and in vitro conditioning of extended length, small diameter vascular grafts.

Authors:  George Fercana; Devon Bowser; Margarita Portilla; Eugene M Langan; Christopher G Carsten; David L Cull; Leslie N Sierad; Dan T Simionescu
Journal:  Tissue Eng Part C Methods       Date:  2014-09-29       Impact factor: 3.056

3.  The performance of cross-linked acellular arterial scaffolds as vascular grafts; pre-clinical testing in direct and isolation loop circulatory models.

Authors:  Timothy Pennel; George Fercana; Deon Bezuidenhout; Agneta Simionescu; Ting-Hsien Chuang; Peter Zilla; Dan Simionescu
Journal:  Biomaterials       Date:  2014-05-09       Impact factor: 12.479

4.  Lower Extremity Arterial Bypass with Arm Vein Conduits and Literature Review.

Authors:  Dae-Joon Park; Yang-Jin Park; Kyoung Won Yoon; Seon-Hee Heo; Dong-Ik Kim; Young-Wook Kim
Journal:  Vasc Specialist Int       Date:  2016-12-31

5.  Results of Infrainguinal Bypass with a Composite Graft Combining Polytetrafluoroethylene and Vein Graft in Absence of Appropriate Saphenous Vein Graft.

Authors:  Myung Jae Jin; Ui Jun Park; Hyoung Tae Kim; Young-Nam Roh
Journal:  Vasc Specialist Int       Date:  2017-06-30

6.  The Effect of Mechanical Overloading on Surface Roughness of the Coronary Arteries.

Authors:  Hanna E Burton; Daniel M Espino
Journal:  Appl Bionics Biomech       Date:  2019-01-23       Impact factor: 1.781

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.