Hardness of celluloid strip-finished or polished composite surfaces with time.

S H Park1, I Krejci, F Lutz.   

Abstract

STATEMENT OF PROBLEM: An in-vitro study revealed that a celluloid strip-finished composite surface discolored more than the polished composite surface. Thus, the celluloid strip-finished composite surface may not cure enough compared with the polished composite surface.
PURPOSE: This study tested the hypothesis that the celluloid strip-finished composite surface did not cure enough compared with the polished composite surface. METHODS AND MATERIAL: The composite was placed in a 1.5-mm thick aluminum mold and the upper surface was covered with a celluloid strip. Composite was light cured for 60 seconds, then a layer of approximately 200 microm thick was ground away from the lower surface and polished. The hardness of the upper composite surface that was polymerized under a celluloid strip and the polished lower surface were measured with Vickers hardness measuring instrument 15 minutes, 6 hours, and 6 days after light curing. The hardnesses of polished and celluloid strip-finished surfaces were compared using a paired t test. One-way ANOVA and Tukey was used for tests for the significant differences in hardnesses between 15 minutes, 6 hours, and 6 days after light curing for a given surface.
RESULTS: Microhardness of the celluloid strip-finished composite surface was 380.6 N/mm(2) at 15 minutes, 442.5 N/mm(2) at 6 hours, and 519.2 N/mm(2) at 6 days after light curing. Microhardnesses of the polished composite surface was 476.6 N/mm(2) at 15 minutes, 511.7 N/mm(2) at 6 hours, and 535.0 N/mm(2) at 6 days after light curing. The hardness of the celluloid strip-opposed composite surface was significantly lower than that of the polished surface 15 minutes and 6 hours after light curing (P <. 001). There was no difference in hardness between the celluloid strip-opposed surface and the polished surface on the sixth day.
CONCLUSION: The hardness of the celluloid strip-opposed composite surface was lower than that of the polished surface at 15 minutes and at 6 hours after light curing. However, there was no difference in microhardness in 6 days.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10842135

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Biofilm formation affects surface properties of novel bioactive glass-containing composites.

Authors:  Hong-Keun Hyun; Satin Salehi; Jack L Ferracane
Journal:  Dent Mater       Date:  2015-11-15       Impact factor: 5.304

2.  Influence of finishing/polishing procedures on the surface texture of two resin composites.

Authors:  Atsushi Kameyama; Taeko Nakazawa; Akiko Haruyama; Chikahiro Haruyama; Makoto Hosaka; Yoshito Hirai
Journal:  Open Dent J       Date:  2008-03-12

3.  Evaluation of the surface hardness of composite resins before and after polishing at different times.

Authors:  Michelle Alexandra Chinelatti; Daniela Thomazatti Chimello; Renata Pereira Ramos; Regina Guenka Palma-Dibb
Journal:  J Appl Oral Sci       Date:  2006-06       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.