Literature DB >> 10842130

Marginal fit of nickel-chromium copings before and after internal adjustments with duplicated stone dies and disclosing agent.

O Ushiwata1, J V de Moraes, M A Bottino, E G da Silva.   

Abstract

STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies.
PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy.
MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment.
RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit.
CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10842130

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

Authors:  Eswaran Bhaskaran; N S Azhagarasan; Saket Miglani; T Ilango; G Phani Krishna; B Gajapathi
Journal:  J Indian Prosthodont Soc       Date:  2013-05-03

2.  Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study.

Authors:  Deepa Alex; Y Bharath Shetty; Glynis Anita Miranda; M Bharath Prabhu; Reshma Karkera
Journal:  J Indian Prosthodont Soc       Date:  2015 Jan-Mar

3.  Comparative evaluation of marginal fit and axial wall adaptability of copings fabricated by metal laser sintering and lost-wax technique: An in vitro study.

Authors:  Bhushan Satish Gaikwad; Girish Nazirkar; Rajani Dable; Shailendra Singh
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

4.  Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses.

Authors:  Halil İbrahim Kılınç; Bülent Kesim; Hasan Önder Gümüş; Mehmet Dinçel; Selçuk Erkaya
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.