Literature DB >> 10835470

Critical appraisal of the design and reporting of studies of imaging and measurement of carotid stenosis.

P M Rothwell1, S T Pendlebury, J Wardlaw, C P Warlow.   

Abstract

BACKGROUND AND
PURPOSE: Several hundred studies have been published over the last few years on imaging and measurement of carotid stenosis. Despite all this research, there is still no consensus about how best to image and measure stenosis. One possible explanation for this is that many of the studies have not been large enough or methodologically sound enough to allow useful conclusions to be drawn. We aimed to assess the design and methods of a random sample of published studies of imaging and measurement of carotid stenosis using 9 simple criteria.
METHODS: A formal literature search was performed for studies of imaging and measurement of carotid stenosis. Two subsets were randomly selected for detailed assessment: 20 studies published before 1991 and 20 published between 1993 and 1997 (some years after the initial publication of the ECST and NASCET trials). The criteria used to assess the selected studies were as follows: prospective rather than retrospective study design; patient selection based on a consecutive series or a random sample; adequate detail of study population; adequate detail of imaging techniques; inclusion of all investigations, ie, patients with poor-quality imaging were not excluded; blinded assessment of images; adequate detail of derivation of measurement of stenosis from images or data; adequate data on the reproducibility of measurements of stenosis; and study powered according to a sample-size calculation.
RESULTS: There were many basic methodological deficiencies in both subsets of studies, with relatively little evidence of improvement with time. For example, only 33% of studies were prospective, only 45% studied a consecutive or random selection of patients, and only 38% reported any data on the reproducibility of measurements. More than half of the studies satisfied < or =4 of the 9 quality criteria. However, there was considerable variation between studies, with 7 studies satisfying > or = 7 criteria and 10 studies satisfying < or =2. No study was based on a sample-size calculation. The number of patients studied was often small, particularly in the more recent studies: median sample size was 100 in the 1970-1990 studies and 58 in the 1993-1997 studies (P<0.0001).
CONCLUSIONS: The design and reporting of published studies of imaging and measurement of carotid stenosis are poor and have not improved much in recent years. The majority of published studies are not of a sufficient standard to enable the results to be used to inform clinical practice. The utility of future studies could be improved considerably by better adherence to 9 simple methodological guidelines.

Entities:  

Mesh:

Year:  2000        PMID: 10835470     DOI: 10.1161/01.str.31.6.1444

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  14 in total

Review 1.  Utility of noninvasive studies in the evaluation of patients with carotid artery disease.

Authors:  Dean C C Johnston; Larry B Goldstein
Journal:  Curr Neurol Neurosci Rep       Date:  2002-01       Impact factor: 5.081

2.  Total occlusion versus hairline residual lumen of the internal carotid arteries: accuracy of single section helical CT angiography.

Authors:  Michael H Lev; Javier M Romero; Daniel N F Goodman; Ranjit Bagga; H Young Kwon Kim; Neil A Clerk; Robert H Ackerman; R Gilberto Gonzalez
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

3.  Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing.

Authors:  M Lell; C Fellner; U Baum; T Hothorn; R Steiner; W Lang; W Bautz; F A Fellner
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

4.  CT angiographic analysis of carotid artery stenosis: comparison of manual assessment, semiautomatic vessel analysis, and digital subtraction angiography.

Authors:  H M Silvennoinen; S Ikonen; L Soinne; M Railo; L Valanne
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

5.  Interobserver agreement for detection of malignant features of intraductal papillary mucinous neoplasms of the pancreas on MDCT.

Authors:  Richard K G Do; Seth S Katz; Marc J Gollub; Jian Li; Jennifer LaFemina; Emily C Zabor; Chaya S Moskowitz; David S Klimstra; Peter J Allen
Journal:  AJR Am J Roentgenol       Date:  2014-11       Impact factor: 3.959

6.  Time-of-flight MR angiography of carotid artery stenosis: does a flow void represent severe stenosis?

Authors:  Paul J Nederkoorn; Yolanda van der Graaf; Bert C Eikelboom; Aad van der Lugt; Lambertus W Bartels; Willem P T M Mali
Journal:  AJNR Am J Neuroradiol       Date:  2002 Nov-Dec       Impact factor: 3.825

Review 7.  Imaging of vertebral artery stenosis: a systematic review.

Authors:  S Khan; G C Cloud; S Kerry; H S Markus
Journal:  J Neurol Neurosurg Psychiatry       Date:  2007-02-07       Impact factor: 10.154

8.  CTA in the detection and quantification of vertebral artery pathologies: a correlation with color Doppler sonography.

Authors:  Stefan Puchner; Markus Haumer; Thomas Rand; Markus Reiter; Erich Minar; Johannes Lammer; Robert A Bucek
Journal:  Neuroradiology       Date:  2007-04-24       Impact factor: 2.804

9.  Grading of carotid artery stenosis with multidetector-row CT angiography: visual estimation or caliper measurements?

Authors:  Annet Waaijer; M Weber; M S van Leeuwen; J Kardux; W B Veldhuis; R Lo; F J A Beek; M Prokop
Journal:  Eur Radiol       Date:  2009-07-18       Impact factor: 5.315

10.  MR imaging: influence of imaging technique and postprocessing on measurement of internal carotid artery stenosis.

Authors:  F Runck; R P Steiner; W A Bautz; M M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2008-07-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.