Literature DB >> 10828931

Femoral artery ischemia during spinal scoliosis surgery detected by posterior tibial nerve somatosensory-evoked potential monitoring.

D G Vossler1, T Stonecipher, M D Millen.   

Abstract

STUDY
DESIGN: A case report of unilateral leg ischemia caused by femoral artery compression detected using posterior tibial nerve somatosensory-evoked potentials during spinal scoliosis instrumentation surgery.
OBJECTIVES: To report a rare cause of intraoperative unilateral loss of all posterior tibial nerve somatosensory-evoked potential waveforms. SUMMARY OF BACKGROUND DATA: Failure to obtain adequate popliteal fossa, spinal, subcortical, and cortical potentials during posterior tibial nerve somatosensory-evoked potential spinal cord monitoring usually results from technical factors or chronic conditions affecting the peripheral nerve.
METHODS: A 16-year-old boy with thoracic scoliosis had normal posterior tibial nerve somatosensory-evoked potentials both before surgery and in the operating room immediately after anesthesia induction and prone positioning on a four-post spinal frame.
RESULTS: One hour after the start of surgery, a minimal amplitude reduction of the right popliteal fossa potentials appeared. Fifteen minutes later, the amplitudes of the popliteal fossa, subcortical, and cortical potentials evoked by right posterior tibial nerve stimulation became substantially reduced. Subsequently, all waveforms were lost. Malfunction of the right posterior tibial nerve stimulator was initially suspected, but when proper function was verified, a search for other causes of this loss led to discovery of leg ischemia. The patient was repositioned on the spinal frame, and all posterior tibial nerve somatosensory-evoked potentials waveforms began to reappear 7 minutes later. There was no postoperative clinically detectable complication.
CONCLUSIONS: Although technical malfunction should always be suspected when all intraoperative somatosensory-evoked potential waveforms are initially seen and subsequently lost, one should also consider the possibility that intraoperative ischemia due to limb positioning could be the etiology.

Entities:  

Mesh:

Year:  2000        PMID: 10828931     DOI: 10.1097/00007632-200006010-00021

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  5 in total

1.  Anterior thigh compartment syndrome after prone positioning for lumbosacral fixation.

Authors:  R Dahab; C Barrett; R Pillay; M De Matas
Journal:  Eur Spine J       Date:  2012-04-07       Impact factor: 3.134

2.  Detection of acute femoral artery ischemia during neuroembolization by somatosensory and motor evoked potential monitoring.

Authors:  David Purger; Abdullah H Feroze; Omar Choudhri; Leslie Lee; Jaime Lopez; Robert L Dodd
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

3.  Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: results in 206 thoracolumbar spine surgeries.

Authors:  David B Macdonald; Zayed Al Zayed; Abdulmoneam Al Saddigi
Journal:  Eur Spine J       Date:  2007-07-19       Impact factor: 3.134

4.  Neurological deterioration as a result of improper neck position detected by intraoperative neurophysiological monitoring in a cervical stenosis patient: A case report.

Authors:  Tong Yu; Jiu-Ping Wu; Tao He; Yao-Kuan Ruan; Qin-Yi Liu
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

5.  Transient Monoplegia as a Result of Unilateral Femoral Artery Ischemia Detected by Multimodal Intraoperative Neuromonitoring in Posterior Scoliosis Surgery: A Case Report.

Authors:  Rafal Pankowski; Marek Roclawski; Krzysztof Dziegiel; Marcin Ceynowa; Marcin Mikulicz; Tomasz Mazurek; Wojciech Kloc
Journal:  Medicine (Baltimore)       Date:  2016-02       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.