Literature DB >> 10828792

Evaluation of the caloric test by combining 3 response parameters.

R Maire1, B Daoui, G Van Melle.   

Abstract

The slow-phase velocity of nystagmus is one of the most sensitive parameters of vestibular function and is currently the standard for evaluating the caloric test. However, the assessment of this parameter requires recording the response by using nystagmography. The aim of this study was to evaluate whether frequency and duration of the caloric nystagmus, as measured by using a clinical test with Frenzel glasses, could predict the result of the recorded test. The retrospective analysis of 222 caloric test results recorded by means of electronystagmography has shown a good association between the 3 parameters for unilateral weakness. The asymmetry observed in the velocity can be predicted by a combination of frequency and duration. On the other hand, no relationship was observed between the parameters for directional preponderance. These results indicate that a clinical caloric test with frequency and duration as parameters can be used to predict the unilateral weakness, which would be obtained by use of nystagmography. We propose an evaluation of the caloric test on the basis of diagrams combining the 3 response parameters.

Entities:  

Mesh:

Year:  2000        PMID: 10828792     DOI: 10.1016/S0194-59980070007-6

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   5.591


  1 in total

1.  From nystagmus to the air and water caloric tests.

Authors:  Anna Carolina Marques Perrella de Barros; Heloisa Helena Caovilla
Journal:  Braz J Otorhinolaryngol       Date:  2012 Jul-Aug