Literature DB >> 10826690

Parameters affecting reproducibility in capillary electrophoresis.

J P Schaeper1, M J Sepaniak.   

Abstract

It is well known that poor quantitative reproducibility substantially limits the practical implementation of capillary electrophoresis (CE) separations in chemical analysis. The principal sources of variance in observed peak areas are irreproducible flow rate, which influences on-column detector response, and inconsistent injection volume or amount. An overview of studies by researchers to address the reproducibility issue will be presented. In addition, current efforts in our laboratory to assess sources of quantitative variance for separations of dansylated amino acids using an automated CE system are presented and related when appropriate to the body of existing knowledge on this important topic. A comparison of different injection methods (hydrostatic vs. electrokinetic) and approaches (e.g., high vs. low pressure), the effect of random changes in electroosmotic flow (EOF) due to air bubbles in the CE capillary, and choice of certain peak integration parameters in terms of peak area reproducibility are presented. Under optimum conditions relative standard deviation (RSD) values in raw peak area are typically 2.0%. With nonoptimum conditions (e.g., with air bubbles in capillary), RSD values can substantially degrade. However, normalizing with retention times, internal standards, or observed electrophoretic current produces RSD values in a range of 1.4-2.3%.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10826690     DOI: 10.1002/(SICI)1522-2683(20000401)21:7<1421::AID-ELPS1421>3.0.CO;2-7

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  High-Throughput Generation of Product Profiles for Arabinoxylan-Active Enzymes from Metagenomes.

Authors:  Maria João Maurício da Fonseca; Zachary Armstrong; Stephen G Withers; Yves Briers
Journal:  Appl Environ Microbiol       Date:  2020-11-10       Impact factor: 4.792

2.  Alternate injections coupled with flow-gated capillary electrophoresis for rapid and accurate quantitative analysis of urine samples.

Authors:  Qingfu Zhu; Qiyang Zhang; Ning Zhang; Maojun Gong
Journal:  Anal Chim Acta       Date:  2017-05-06       Impact factor: 6.558

3.  Novel volumetric method for highly repeatable injection in microchip electrophoresis.

Authors:  Noel S Ha; Jimmy Ly; Jason Jones; Shilin Cheung; R Michael van Dam
Journal:  Anal Chim Acta       Date:  2017-06-19       Impact factor: 6.558

4.  Improving repeatability of capillary electrophoresis-a critical comparison of ten different capillary inner surfaces and three criteria of peak identification.

Authors:  Paweł Mateusz Nowak; Michał Woźniakiewicz; Marta Gładysz; Magdalena Janus; Paweł Kościelniak
Journal:  Anal Bioanal Chem       Date:  2017-05-08       Impact factor: 4.142

5.  The First Online Capillary Electrophoresis-Microscale Thermophoresis (CE-MST) Method for the Analysis of Dynamic Equilibria-The Determination of the Acidity Constant of Fluorescein Isothiocyanate.

Authors:  Paweł Mateusz Nowak; Maria Klag; Gabriela Kózka; Małgorzata Gołąb; Michał Woźniakiewicz
Journal:  Molecules       Date:  2022-08-06       Impact factor: 4.927

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.