Literature DB >> 10825146

Comparison of TP53 mutations identified by oligonucleotide microarray and conventional DNA sequence analysis.

W H Wen1, L Bernstein, J Lescallett, Y Beazer-Barclay, J Sullivan-Halley, M White, M F Press.   

Abstract

As the rate of gene discovery accelerates, more efficient methods are needed to analyze genes in human tissues. To assess the efficiency, sensitivity, and specificity of different methods, alterations of TP53 were independently evaluated in 108 ovarian tumors by conventional DNA sequence analysis and oligonucleotide microarray (p53 GeneChip). All mutations identified by oligonucleotide microarray and all disagreements with conventional gel-based DNA sequence analysis were confirmed by re-analysis with manual and automated dideoxy DNA sequencing. A total of 77 ovarian cancers were identified as having TP53 mutations by one of the two approaches, 71 by microarray and 63 by gel-based DNA sequence analysis. The same mutation was identified in 57 ovarian cancers, and the same wild type TP53 sequence was observed in 31 ovarian cancers by both methods, for a concordance rate of 81%. Among the mutation analyses discordant by these methods for TP53 sequence were 14 cases identified as mutated by microarray but not by conventional DNA sequence analysis and 6 cases identified as mutated by conventional DNA sequence analysis but not by microarray. Overall, the oligonucleotide microarray demonstrated a 94% accuracy rate, a 92% sensitivity, and an 100% specificity. Conventional DNA sequence analysis demonstrated an 87% accuracy rate, 82% sensitivity, and a 100% specificity. Patients with TP53 mutations had significantly shorter overall survival than those with no mutation (P = 0.02). Women with mutations in loop2, loop3, or the loop-sheet-helix domain had shorter survival than women with other mutations or women with no mutations (P = 0.01). Although further refinement would be helpful to improve the detection of certain types of TPS3 alterations, oligonucleotide microarrays were shown to be a powerful and effective tool for TP53 mutation detection.

Entities:  

Mesh:

Year:  2000        PMID: 10825146

Source DB:  PubMed          Journal:  Cancer Res        ISSN: 0008-5472            Impact factor:   12.701


  20 in total

1.  Blinded study determination of high sensitivity and specificity microchip electrophoresis-SSCP/HA to detect mutations in the p53 gene.

Authors:  Christa N Hestekin; Jennifer S Lin; Lionel Senderowicz; John P Jakupciak; Catherine O'Connell; Alfred Rademaker; Annelise E Barron
Journal:  Electrophoresis       Date:  2011-10-17       Impact factor: 3.535

2.  Specific mutation screening of TP53 gene by low-density DNA microarray.

Authors:  Angélica Rangel-López; Alfonso Méndez-Tenorio; Kenneth L Beattie; Rogelio Maldonado; Patricia Mendoza; Guelaguetza Vázquez; Carlos Pérez-Plasencia; Martha Sánchez; Guillermo Navarro; Mauricio Salcedo
Journal:  Nanotechnol Sci Appl       Date:  2009-01-20

3.  Microarray applications in cancer research.

Authors:  Il-Jin Kim; Hio Chung Kang; Jae-Gahb Park
Journal:  Cancer Res Treat       Date:  2004-08-31       Impact factor: 4.679

4.  Pathological characteristics of BRCA-associated breast cancers in Hispanics.

Authors:  Veronica I Lagos-Jaramillo; Michael F Press; Charité N Ricker; Louis Dubeau; Phuong L Mai; Jeffrey N Weitzel
Journal:  Breast Cancer Res Treat       Date:  2011-05-21       Impact factor: 4.872

5.  Microarray-based method for detecting methylation changes of p16(Ink4a) gene 5'-CpG islands in gastric carcinomas.

Authors:  Peng Hou; Jia-Yao Shen; Mei-Ju Ji; Nong-Yue He; Zu-Hong Lu
Journal:  World J Gastroenterol       Date:  2004-12-15       Impact factor: 5.742

6.  Methylation-specific oligonucleotide microarray: a new potential for high-throughput methylation analysis.

Authors:  Raad S Gitan; Huidong Shi; Chuan-Mu Chen; Pearlly S Yan; Tim Hui-Ming Huang
Journal:  Genome Res       Date:  2002-01       Impact factor: 9.043

7.  Evaluating the arrayed primer extension resequencing assay of TP53 tumor suppressor gene.

Authors:  Neeme Tõnisson; Jana Zernant; Ants Kurg; Hendrik Pavel; Georg Slavin; Hanno Roomere; Aune Meiel; Pierre Hainaut; Andres Metspalu
Journal:  Proc Natl Acad Sci U S A       Date:  2002-04-16       Impact factor: 11.205

8.  High sensitivity EndoV mutation scanning through real-time ligase proofreading.

Authors:  Hanna Pincas; Maneesh R Pingle; Jianmin Huang; Kaiqin Lao; Philip B Paty; Alan M Friedman; Francis Barany
Journal:  Nucleic Acids Res       Date:  2004-10-28       Impact factor: 16.971

9.  Oligonucleotide microarrays demonstrate the highest frequency of ATM mutations in the mantle cell subtype of lymphoma.

Authors:  Nicole Y Fang; Timothy C Greiner; Dennis D Weisenburger; Wing C Chan; Julie M Vose; Lynette M Smith; James O Armitage; R Aeryn Mayer; Brian L Pike; Francis S Collins; Joseph G Hacia
Journal:  Proc Natl Acad Sci U S A       Date:  2003-04-15       Impact factor: 11.205

10.  The Human MitoChip: a high-throughput sequencing microarray for mitochondrial mutation detection.

Authors:  Anirban Maitra; Yoram Cohen; Susannah E D Gillespie; Elizabeth Mambo; Noriyoshi Fukushima; Mohammad O Hoque; Nila Shah; Michael Goggins; Joseph Califano; David Sidransky; Aravinda Chakravarti
Journal:  Genome Res       Date:  2004-05       Impact factor: 9.043

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.