Literature DB >> 10823084

Effect of saliva contamination on the bond of dentin to resin-modified glass-ionomer cement.

J A Safar1, R D Davis, J D Overton.   

Abstract

This in vitro study compared the shear bond strength of a resin-modified glass-ionomer restorative material (Fuji II LC) bonded to saliva-contaminated dentin versus non-contaminated dentin. Seventy-five extracted human molar teeth were randomly divided into five groups of 15 samples each. The dentin was treated with 10% polyacrylic acid for 20 seconds, rinsed, and dried. The acid-treated dentin surfaces in Groups 1-4 were contaminated with saliva. In Group 1, the saliva was air thinned. In Groups 2-4, saliva was dried completely with compressed air. The saliva-contaminated dentin in Group 3 was rinsed and dried. The saliva-contaminated dentin in Group 4 was rinsed, dried, treated with 10% polyacrylic acid, and dried. Specimens in Group 5 received no contamination. The resin-modified glass-ionomer cement restorative material was mixed and applied to the dentin surfaces. Following placement of the restorative material and 7 days of storage, the specimens were thermo-cycled 300 times. Using the Instron Universal Testing Machine, a shear force was applied to the restorative material. Shear bond strength values were compared among the groups using a one-way ANOVA and Student-Neuman-Keuls Multiple Range Test (alpha = 0.05). The non-contaminated specimens (Group 5) were significantly stronger than the contaminated specimens (Groups 1-4). There were no significant differences in bond strength among the groups containing contaminated specimens. Salivary contamination occurring after dentin etching significantly reduced the bond strength of the resin-modified glass-ionomer restorative material to dentin. Neither rinsing nor rinsing and re-etching resulted in bond strengths as great as to non-contaminated dentin.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10823084

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  7 in total

1.  Effect of mucoprotein on the bond strength of resin composite to human dentin.

Authors:  Lilliam Marie Pinzon; John M Powers; Kathy L O'Keefe; Vladimir Dusevish; Paulette Spencer; Grayson W Marshall
Journal:  Odontology       Date:  2011-04-23       Impact factor: 2.634

Review 2.  Factors affecting in vitro bond strength of bonding agents to human dentin.

Authors:  John M Powers; Kathy L O'Keefe; Lilliam M Pinzon
Journal:  Odontology       Date:  2003-09       Impact factor: 2.634

3.  Short communication: Influence of different isolation methods on the survival of proximal ART restorations in primary molars after two years.

Authors:  A M Kemoli; W E van Amerongen; G N Opinya
Journal:  Eur Arch Paediatr Dent       Date:  2010-06

4.  In vitro evaluation of different dental materials used for the treatment of extensive cervical root defects using human periodontal cells.

Authors:  Annemarie Michel; Ralf Erber; Cornelia Frese; Holger Gehrig; Daniel Saure; Johannes Mente
Journal:  Clin Oral Investig       Date:  2016-05-14       Impact factor: 3.573

5.  Choice of cement for single-unit crowns: Findings from The National Dental Practice-Based Research Network.

Authors:  Nathaniel C Lawson; Mark S Litaker; Jack L Ferracane; Valeria V Gordan; Alan M Atlas; Tara Rios; Gregg H Gilbert; Michael S McCracken
Journal:  J Am Dent Assoc       Date:  2019-04-25       Impact factor: 3.634

6.  In vitro evaluation of influence of salivary contamination on the dentin bond strength of one-bottle adhesive systems.

Authors:  Nujella B P Suryakumari; P Satyanarayana Reddy; L R Surender; Ram Kiran
Journal:  Contemp Clin Dent       Date:  2011-07

7.  Effect of saliva and blood contamination on the shear bond strength of fifth-, seventh-, and eighth-generation bonding agents: An in vitro study.

Authors:  Sonali Taneja; Manju Kumari; Shreya Bansal
Journal:  J Conserv Dent       Date:  2017 May-Jun
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.